Basler_UniversalTLParams#
Classes#
Name | |
---|---|
class | Basler_UniversalTLParams::CUniversalTLParams_Params A parameter class containing all parameters as members that are available for pylon device transport layers. |
class | Basler_UniversalTLParams::CUniversalTLParams_Params_v7_4_0 A parameter class containing all parameters as members that are available for pylon device transport layers. |
Types#
Name | |
---|---|
enum | AreaTriggerModeEnums { AreaTriggerMode_External, AreaTriggerMode_Generator, AreaTriggerMode_Software, AreaTriggerMode_Synchronized} Valid values for AreaTriggerMode. |
enum | BitAlignmentEnums { BitAlignment_CustomBitShift, BitAlignment_LeftAligned, BitAlignment_RightAligned} Valid values for BitAlignment. |
enum | CxpLinkConfigurationEnums { CxpLinkConfiguration_Auto, CxpLinkConfiguration_CXP10_X1, CxpLinkConfiguration_CXP10_X2, CxpLinkConfiguration_CXP10_X3, CxpLinkConfiguration_CXP10_X4, CxpLinkConfiguration_CXP12_X1, CxpLinkConfiguration_CXP12_X2, CxpLinkConfiguration_CXP12_X3, CxpLinkConfiguration_CXP12_X4, CxpLinkConfiguration_CXP1_X1, CxpLinkConfiguration_CXP1_X2, CxpLinkConfiguration_CXP1_X3, CxpLinkConfiguration_CXP1_X4, CxpLinkConfiguration_CXP2_X1, CxpLinkConfiguration_CXP2_X2, CxpLinkConfiguration_CXP2_X3, CxpLinkConfiguration_CXP2_X4, CxpLinkConfiguration_CXP3_X1, CxpLinkConfiguration_CXP3_X2, CxpLinkConfiguration_CXP3_X3, CxpLinkConfiguration_CXP3_X4, CxpLinkConfiguration_CXP5_X1, CxpLinkConfiguration_CXP5_X2, CxpLinkConfiguration_CXP5_X3, CxpLinkConfiguration_CXP5_X4, CxpLinkConfiguration_CXP6_X1, CxpLinkConfiguration_CXP6_X2, CxpLinkConfiguration_CXP6_X3, CxpLinkConfiguration_CXP6_X4} Valid values for CxpLinkConfiguration. |
enum | CxpTriggerPacketModeEnums { CxpTriggerPacketMode_CXPTriggerRising, CxpTriggerPacketMode_CXPTriggerStandard} Valid values for CxpTriggerPacketMode. |
enum | DeviceAccessStatusEnums { DeviceAccessStatus_Busy, DeviceAccessStatus_NoAccess, DeviceAccessStatus_OpenReadOnly, DeviceAccessStatus_OpenReadWrite, DeviceAccessStatus_ReadOnly, DeviceAccessStatus_ReadWrite, DeviceAccessStatus_Unknown} Valid values for DeviceAccessStatus. |
enum | DeviceEndianessMechanismEnums { DeviceEndianessMechanism_Legacy, DeviceEndianessMechanism_Standard} Valid values for DeviceEndianessMechanism. |
enum | DeviceTypeEnums { DeviceType_CL, DeviceType_CLHS, DeviceType_CXP, DeviceType_CameraLink, DeviceType_CameraLinkHS, DeviceType_CoaXPress, DeviceType_Custom, DeviceType_GEV, DeviceType_GigEVision, DeviceType_Mixed, DeviceType_U3V, DeviceType_USB3Vision} Valid values for DeviceType. |
enum | EventNotificationEnums { EventNotification_Off, EventNotification_On, EventNotification_Once} Valid values for EventNotification. |
enum | EventSelectorEnums { EventSelector_AcquisitionTrigger, EventSelector_DeviceLost, EventSelector_FrameTransferEnd, EventSelector_FrameTransferStart, EventSelector_FrameTriggerMissed, EventSelector_Overflow, EventSelector_TriggerExceededPeriodLimits, EventSelector_TriggerQueueFilllevelThresholdOff, EventSelector_TriggerQueueFilllevelThresholdOn} Valid values for EventSelector. |
enum | FormatEnums { Format_BGR10p, Format_BGR12p, Format_BGR14p, Format_BGR16, Format_BGR8, Format_BGRa8, Format_BayerBG10p, Format_BayerBG12p, Format_BayerBG14p, Format_BayerBG16, Format_BayerBG8, Format_BayerGB10p, Format_BayerGB12p, Format_BayerGB14p, Format_BayerGB16, Format_BayerGB8, Format_BayerGR10p, Format_BayerGR12p, Format_BayerGR14p, Format_BayerGR16, Format_BayerGR8, Format_BayerRG10p, Format_BayerRG12p, Format_BayerRG14p, Format_BayerRG16, Format_BayerRG8, Format_Mono10p, Format_Mono12p, Format_Mono14p, Format_Mono16, Format_Mono8, Format_RGB10p, Format_RGB12p, Format_RGB14p, Format_RGB16, Format_RGB8, Format_RGBa8, Format_YCbCr422_8} Valid values for Format. |
enum | LutEnableEnums { LutEnable_Off, LutEnable_On} Valid values for LutEnable. |
enum | LutImplementationTypeEnums { LutImplementationType_FullLUT, LutImplementationType_KneeLUT} Valid values for LutImplementationType. |
enum | LutTypeEnums { LutType_Processor, LutType_UserFile} Valid values for LutType. |
enum | MissingCameraFrameResponseEnums { MissingCameraFrameResponse_No, MissingCameraFrameResponse_Yes} Valid values for MissingCameraFrameResponse. |
enum | OverflowEventSelectEnums { OverflowEventSelect_All, OverflowEventSelect_Incomplete, OverflowEventSelect_IncompleteLost, OverflowEventSelect_IncompleteOK, OverflowEventSelect_Lost, OverflowEventSelect_LostOK, OverflowEventSelect_OK} Valid values for OverflowEventSelect. |
enum | PixelFormatEnums { PixelFormat_BayerBG10p, PixelFormat_BayerBG12p, PixelFormat_BayerBG14p, PixelFormat_BayerBG8, PixelFormat_BayerGB10p, PixelFormat_BayerGB12p, PixelFormat_BayerGB14p, PixelFormat_BayerGB8, PixelFormat_BayerGR10p, PixelFormat_BayerGR12p, PixelFormat_BayerGR14p, PixelFormat_BayerGR8, PixelFormat_BayerRG10p, PixelFormat_BayerRG12p, PixelFormat_BayerRG14p, PixelFormat_BayerRG8, PixelFormat_Mono10, PixelFormat_Mono10p, PixelFormat_Mono12, PixelFormat_Mono12p, PixelFormat_Mono14p, PixelFormat_Mono16, PixelFormat_Mono8, PixelFormat_RGB10p, PixelFormat_RGB12p, PixelFormat_RGB14p, PixelFormat_RGB16, PixelFormat_RGB8, PixelFormat_YCbCr422_8} Valid values for PixelFormat. |
enum | ProcessingInvertEnums { ProcessingInvert_Off, ProcessingInvert_On} Valid values for ProcessingInvert. |
enum | SoftwareTriggerIsBusyEnums { SoftwareTriggerIsBusy_Busy, SoftwareTriggerIsBusy_NotBusy} Valid values for SoftwareTriggerIsBusy. |
enum | SystemmonitorByteAlignment8b10bLockedEnums { SystemmonitorByteAlignment8b10bLocked_No, SystemmonitorByteAlignment8b10bLocked_Yes} Valid values for SystemmonitorByteAlignment8b10bLocked. |
enum | SystemmonitorExternalPowerEnums { SystemmonitorExternalPower_NoPower, SystemmonitorExternalPower_PowerGood} Valid values for SystemmonitorExternalPower. |
enum | SystemmonitorPowerOverCxpStateEnums { SystemmonitorPowerOverCxpState_PoCXPADCChipError, SystemmonitorPowerOverCxpState_PoCXPBooting, SystemmonitorPowerOverCxpState_PoCXPDisabled, SystemmonitorPowerOverCxpState_PoCXPLowVolt, SystemmonitorPowerOverCxpState_PoCXPMaxCurrent, SystemmonitorPowerOverCxpState_PoCXPMinCurrent, SystemmonitorPowerOverCxpState_PoCXPNotConnected, SystemmonitorPowerOverCxpState_PoCXPOK, SystemmonitorPowerOverCxpState_PoCXPOverVolt} Valid values for SystemmonitorPowerOverCxpState. |
enum | TriggerCameraOutSelectEnums { TriggerCameraOutSelect_BypassFrontGPI0, TriggerCameraOutSelect_BypassFrontGPI1, TriggerCameraOutSelect_BypassFrontGPI2, TriggerCameraOutSelect_BypassFrontGPI3, TriggerCameraOutSelect_BypassGPI0, TriggerCameraOutSelect_BypassGPI1, TriggerCameraOutSelect_BypassGPI2, TriggerCameraOutSelect_BypassGPI3, TriggerCameraOutSelect_BypassGPI4, TriggerCameraOutSelect_BypassGPI5, TriggerCameraOutSelect_BypassGPI6, TriggerCameraOutSelect_BypassGPI7, TriggerCameraOutSelect_CamAPulseGenerator0, TriggerCameraOutSelect_CamAPulseGenerator1, TriggerCameraOutSelect_CamAPulseGenerator2, TriggerCameraOutSelect_CamAPulseGenerator3, TriggerCameraOutSelect_CamBPulseGenerator0, TriggerCameraOutSelect_CamBPulseGenerator1, TriggerCameraOutSelect_CamBPulseGenerator2, TriggerCameraOutSelect_CamBPulseGenerator3, TriggerCameraOutSelect_CamCPulseGenerator0, TriggerCameraOutSelect_CamCPulseGenerator1, TriggerCameraOutSelect_CamCPulseGenerator2, TriggerCameraOutSelect_CamCPulseGenerator3, TriggerCameraOutSelect_CamDPulseGenerator0, TriggerCameraOutSelect_CamDPulseGenerator1, TriggerCameraOutSelect_CamDPulseGenerator2, TriggerCameraOutSelect_CamDPulseGenerator3, TriggerCameraOutSelect_GND, TriggerCameraOutSelect_NotBypassFronGPI0, TriggerCameraOutSelect_NotBypassFronGPI1, TriggerCameraOutSelect_NotBypassFronGPI2, TriggerCameraOutSelect_NotBypassFronGPI3, TriggerCameraOutSelect_NotBypassFrontGPI0, TriggerCameraOutSelect_NotBypassFrontGPI1, TriggerCameraOutSelect_NotBypassFrontGPI2, TriggerCameraOutSelect_NotBypassFrontGPI3, TriggerCameraOutSelect_NotBypassGPI0, TriggerCameraOutSelect_NotBypassGPI1, TriggerCameraOutSelect_NotBypassGPI2, TriggerCameraOutSelect_NotBypassGPI3, TriggerCameraOutSelect_NotBypassGPI4, TriggerCameraOutSelect_NotBypassGPI5, TriggerCameraOutSelect_NotBypassGPI6, TriggerCameraOutSelect_NotBypassGPI7, TriggerCameraOutSelect_NotCamAPulseGenerator0, TriggerCameraOutSelect_NotCamAPulseGenerator1, TriggerCameraOutSelect_NotCamAPulseGenerator2, TriggerCameraOutSelect_NotCamAPulseGenerator3, TriggerCameraOutSelect_NotCamBPulseGenerator0, TriggerCameraOutSelect_NotCamBPulseGenerator1, TriggerCameraOutSelect_NotCamBPulseGenerator2, TriggerCameraOutSelect_NotCamBPulseGenerator3, TriggerCameraOutSelect_NotCamCPulseGenerator0, TriggerCameraOutSelect_NotCamCPulseGenerator1, TriggerCameraOutSelect_NotCamCPulseGenerator2, TriggerCameraOutSelect_NotCamCPulseGenerator3, TriggerCameraOutSelect_NotCamDPulseGenerator0, TriggerCameraOutSelect_NotCamDPulseGenerator1, TriggerCameraOutSelect_NotCamDPulseGenerator2, TriggerCameraOutSelect_NotCamDPulseGenerator3, TriggerCameraOutSelect_NotPulseGenerator0, TriggerCameraOutSelect_NotPulseGenerator1, TriggerCameraOutSelect_NotPulseGenerator2, TriggerCameraOutSelect_NotPulseGenerator3, TriggerCameraOutSelect_PulseGenerator0, TriggerCameraOutSelect_PulseGenerator1, TriggerCameraOutSelect_PulseGenerator2, TriggerCameraOutSelect_PulseGenerator3, TriggerCameraOutSelect_VCC} Valid values for TriggerCameraOutSelect. |
enum | TriggerExceededPeriodLimitsEnums { TriggerExceededPeriodLimits_No, TriggerExceededPeriodLimits_Yes} Valid values for TriggerExceededPeriodLimits. |
enum | TriggerInPolarityEnums { TriggerInPolarity_HighActive, TriggerInPolarity_LowActive} Valid values for TriggerInPolarity. |
enum | TriggerInSourceEnums { TriggerInSource_GPITriggerSource0, TriggerInSource_GPITriggerSource1, TriggerInSource_GPITriggerSource2, TriggerInSource_GPITriggerSource3, TriggerInSource_GPITriggerSource4, TriggerInSource_GPITriggerSource5, TriggerInSource_GPITriggerSource6, TriggerInSource_GPITriggerSource7, TriggerInSource_TriggerInSourceFrontGPI0, TriggerInSource_TriggerInSourceFrontGPI1, TriggerInSource_TriggerInSourceFrontGPI2, TriggerInSource_TriggerInSourceFrontGPI3} Valid values for TriggerInSource. |
enum | TriggerInStatisticsPolarityEnums { TriggerInStatisticsPolarity_HighActive, TriggerInStatisticsPolarity_LowActive} Valid values for TriggerInStatisticsPolarity. |
enum | TriggerInStatisticsSourceEnums { TriggerInStatisticsSource_GPITriggerSource0, TriggerInStatisticsSource_GPITriggerSource1, TriggerInStatisticsSource_GPITriggerSource2, TriggerInStatisticsSource_GPITriggerSource3, TriggerInStatisticsSource_GPITriggerSource4, TriggerInStatisticsSource_GPITriggerSource5, TriggerInStatisticsSource_GPITriggerSource6, TriggerInStatisticsSource_GPITriggerSource7, TriggerInStatisticsSource_TriggerInSourceFrontGPI0, TriggerInStatisticsSource_TriggerInSourceFrontGPI1, TriggerInStatisticsSource_TriggerInSourceFrontGPI2, TriggerInStatisticsSource_TriggerInSourceFrontGPI3} Valid values for TriggerInStatisticsSource. |
enum | TriggerOutSelectFrontGPO0Enums { TriggerOutSelectFrontGPO0_BypassFrontGPI0, TriggerOutSelectFrontGPO0_BypassFrontGPI1, TriggerOutSelectFrontGPO0_BypassFrontGPI2, TriggerOutSelectFrontGPO0_BypassFrontGPI3, TriggerOutSelectFrontGPO0_BypassGPI0, TriggerOutSelectFrontGPO0_BypassGPI1, TriggerOutSelectFrontGPO0_BypassGPI2, TriggerOutSelectFrontGPO0_BypassGPI3, TriggerOutSelectFrontGPO0_BypassGPI4, TriggerOutSelectFrontGPO0_BypassGPI5, TriggerOutSelectFrontGPO0_BypassGPI6, TriggerOutSelectFrontGPO0_BypassGPI7, TriggerOutSelectFrontGPO0_CamAPulseGenerator0, TriggerOutSelectFrontGPO0_CamAPulseGenerator1, TriggerOutSelectFrontGPO0_CamAPulseGenerator2, TriggerOutSelectFrontGPO0_CamAPulseGenerator3, TriggerOutSelectFrontGPO0_CamBPulseGenerator0, TriggerOutSelectFrontGPO0_CamBPulseGenerator1, TriggerOutSelectFrontGPO0_CamBPulseGenerator2, TriggerOutSelectFrontGPO0_CamBPulseGenerator3, TriggerOutSelectFrontGPO0_CamCPulseGenerator0, TriggerOutSelectFrontGPO0_CamCPulseGenerator1, TriggerOutSelectFrontGPO0_CamCPulseGenerator2, TriggerOutSelectFrontGPO0_CamCPulseGenerator3, TriggerOutSelectFrontGPO0_CamDPulseGenerator0, TriggerOutSelectFrontGPO0_CamDPulseGenerator1, TriggerOutSelectFrontGPO0_CamDPulseGenerator2, TriggerOutSelectFrontGPO0_CamDPulseGenerator3, TriggerOutSelectFrontGPO0_GND, TriggerOutSelectFrontGPO0_NotBypassFronGPI0, TriggerOutSelectFrontGPO0_NotBypassFronGPI1, TriggerOutSelectFrontGPO0_NotBypassFronGPI2, TriggerOutSelectFrontGPO0_NotBypassFronGPI3, TriggerOutSelectFrontGPO0_NotBypassFrontGPI0, TriggerOutSelectFrontGPO0_NotBypassFrontGPI1, TriggerOutSelectFrontGPO0_NotBypassFrontGPI2, TriggerOutSelectFrontGPO0_NotBypassFrontGPI3, TriggerOutSelectFrontGPO0_NotBypassGPI0, TriggerOutSelectFrontGPO0_NotBypassGPI1, TriggerOutSelectFrontGPO0_NotBypassGPI2, TriggerOutSelectFrontGPO0_NotBypassGPI3, TriggerOutSelectFrontGPO0_NotBypassGPI4, TriggerOutSelectFrontGPO0_NotBypassGPI5, TriggerOutSelectFrontGPO0_NotBypassGPI6, TriggerOutSelectFrontGPO0_NotBypassGPI7, TriggerOutSelectFrontGPO0_NotCamAPulseGenerator0, TriggerOutSelectFrontGPO0_NotCamAPulseGenerator1, TriggerOutSelectFrontGPO0_NotCamAPulseGenerator2, TriggerOutSelectFrontGPO0_NotCamAPulseGenerator3, TriggerOutSelectFrontGPO0_NotCamBPulseGenerator0, TriggerOutSelectFrontGPO0_NotCamBPulseGenerator1, TriggerOutSelectFrontGPO0_NotCamBPulseGenerator2, TriggerOutSelectFrontGPO0_NotCamBPulseGenerator3, TriggerOutSelectFrontGPO0_NotCamCPulseGenerator0, TriggerOutSelectFrontGPO0_NotCamCPulseGenerator1, TriggerOutSelectFrontGPO0_NotCamCPulseGenerator2, TriggerOutSelectFrontGPO0_NotCamCPulseGenerator3, TriggerOutSelectFrontGPO0_NotCamDPulseGenerator0, TriggerOutSelectFrontGPO0_NotCamDPulseGenerator1, TriggerOutSelectFrontGPO0_NotCamDPulseGenerator2, TriggerOutSelectFrontGPO0_NotCamDPulseGenerator3, TriggerOutSelectFrontGPO0_NotPulseGenerator0, TriggerOutSelectFrontGPO0_NotPulseGenerator1, TriggerOutSelectFrontGPO0_NotPulseGenerator2, TriggerOutSelectFrontGPO0_NotPulseGenerator3, TriggerOutSelectFrontGPO0_PulseGenerator0, TriggerOutSelectFrontGPO0_PulseGenerator1, TriggerOutSelectFrontGPO0_PulseGenerator2, TriggerOutSelectFrontGPO0_PulseGenerator3, TriggerOutSelectFrontGPO0_VCC} Valid values for TriggerOutSelectFrontGPO0. |
enum | TriggerOutSelectFrontGPO1Enums { TriggerOutSelectFrontGPO1_BypassFrontGPI0, TriggerOutSelectFrontGPO1_BypassFrontGPI1, TriggerOutSelectFrontGPO1_BypassFrontGPI2, TriggerOutSelectFrontGPO1_BypassFrontGPI3, TriggerOutSelectFrontGPO1_BypassGPI0, TriggerOutSelectFrontGPO1_BypassGPI1, TriggerOutSelectFrontGPO1_BypassGPI2, TriggerOutSelectFrontGPO1_BypassGPI3, TriggerOutSelectFrontGPO1_BypassGPI4, TriggerOutSelectFrontGPO1_BypassGPI5, TriggerOutSelectFrontGPO1_BypassGPI6, TriggerOutSelectFrontGPO1_BypassGPI7, TriggerOutSelectFrontGPO1_CamAPulseGenerator0, TriggerOutSelectFrontGPO1_CamAPulseGenerator1, TriggerOutSelectFrontGPO1_CamAPulseGenerator2, TriggerOutSelectFrontGPO1_CamAPulseGenerator3, TriggerOutSelectFrontGPO1_CamBPulseGenerator0, TriggerOutSelectFrontGPO1_CamBPulseGenerator1, TriggerOutSelectFrontGPO1_CamBPulseGenerator2, TriggerOutSelectFrontGPO1_CamBPulseGenerator3, TriggerOutSelectFrontGPO1_CamCPulseGenerator0, TriggerOutSelectFrontGPO1_CamCPulseGenerator1, TriggerOutSelectFrontGPO1_CamCPulseGenerator2, TriggerOutSelectFrontGPO1_CamCPulseGenerator3, TriggerOutSelectFrontGPO1_CamDPulseGenerator0, TriggerOutSelectFrontGPO1_CamDPulseGenerator1, TriggerOutSelectFrontGPO1_CamDPulseGenerator2, TriggerOutSelectFrontGPO1_CamDPulseGenerator3, TriggerOutSelectFrontGPO1_GND, TriggerOutSelectFrontGPO1_NotBypassFronGPI0, TriggerOutSelectFrontGPO1_NotBypassFronGPI1, TriggerOutSelectFrontGPO1_NotBypassFronGPI2, TriggerOutSelectFrontGPO1_NotBypassFronGPI3, TriggerOutSelectFrontGPO1_NotBypassFrontGPI0, TriggerOutSelectFrontGPO1_NotBypassFrontGPI1, TriggerOutSelectFrontGPO1_NotBypassFrontGPI2, TriggerOutSelectFrontGPO1_NotBypassFrontGPI3, TriggerOutSelectFrontGPO1_NotBypassGPI0, TriggerOutSelectFrontGPO1_NotBypassGPI1, TriggerOutSelectFrontGPO1_NotBypassGPI2, TriggerOutSelectFrontGPO1_NotBypassGPI3, TriggerOutSelectFrontGPO1_NotBypassGPI4, TriggerOutSelectFrontGPO1_NotBypassGPI5, TriggerOutSelectFrontGPO1_NotBypassGPI6, TriggerOutSelectFrontGPO1_NotBypassGPI7, TriggerOutSelectFrontGPO1_NotCamAPulseGenerator0, TriggerOutSelectFrontGPO1_NotCamAPulseGenerator1, TriggerOutSelectFrontGPO1_NotCamAPulseGenerator2, TriggerOutSelectFrontGPO1_NotCamAPulseGenerator3, TriggerOutSelectFrontGPO1_NotCamBPulseGenerator0, TriggerOutSelectFrontGPO1_NotCamBPulseGenerator1, TriggerOutSelectFrontGPO1_NotCamBPulseGenerator2, TriggerOutSelectFrontGPO1_NotCamBPulseGenerator3, TriggerOutSelectFrontGPO1_NotCamCPulseGenerator0, TriggerOutSelectFrontGPO1_NotCamCPulseGenerator1, TriggerOutSelectFrontGPO1_NotCamCPulseGenerator2, TriggerOutSelectFrontGPO1_NotCamCPulseGenerator3, TriggerOutSelectFrontGPO1_NotCamDPulseGenerator0, TriggerOutSelectFrontGPO1_NotCamDPulseGenerator1, TriggerOutSelectFrontGPO1_NotCamDPulseGenerator2, TriggerOutSelectFrontGPO1_NotCamDPulseGenerator3, TriggerOutSelectFrontGPO1_NotPulseGenerator0, TriggerOutSelectFrontGPO1_NotPulseGenerator1, TriggerOutSelectFrontGPO1_NotPulseGenerator2, TriggerOutSelectFrontGPO1_NotPulseGenerator3, TriggerOutSelectFrontGPO1_PulseGenerator0, TriggerOutSelectFrontGPO1_PulseGenerator1, TriggerOutSelectFrontGPO1_PulseGenerator2, TriggerOutSelectFrontGPO1_PulseGenerator3, TriggerOutSelectFrontGPO1_VCC} Valid values for TriggerOutSelectFrontGPO1. |
enum | TriggerOutSelectGPO0Enums { TriggerOutSelectGPO0_BypassFrontGPI0, TriggerOutSelectGPO0_BypassFrontGPI1, TriggerOutSelectGPO0_BypassFrontGPI2, TriggerOutSelectGPO0_BypassFrontGPI3, TriggerOutSelectGPO0_BypassGPI0, TriggerOutSelectGPO0_BypassGPI1, TriggerOutSelectGPO0_BypassGPI2, TriggerOutSelectGPO0_BypassGPI3, TriggerOutSelectGPO0_BypassGPI4, TriggerOutSelectGPO0_BypassGPI5, TriggerOutSelectGPO0_BypassGPI6, TriggerOutSelectGPO0_BypassGPI7, TriggerOutSelectGPO0_CamAPulseGenerator0, TriggerOutSelectGPO0_CamAPulseGenerator1, TriggerOutSelectGPO0_CamAPulseGenerator2, TriggerOutSelectGPO0_CamAPulseGenerator3, TriggerOutSelectGPO0_CamBPulseGenerator0, TriggerOutSelectGPO0_CamBPulseGenerator1, TriggerOutSelectGPO0_CamBPulseGenerator2, TriggerOutSelectGPO0_CamBPulseGenerator3, TriggerOutSelectGPO0_CamCPulseGenerator0, TriggerOutSelectGPO0_CamCPulseGenerator1, TriggerOutSelectGPO0_CamCPulseGenerator2, TriggerOutSelectGPO0_CamCPulseGenerator3, TriggerOutSelectGPO0_CamDPulseGenerator0, TriggerOutSelectGPO0_CamDPulseGenerator1, TriggerOutSelectGPO0_CamDPulseGenerator2, TriggerOutSelectGPO0_CamDPulseGenerator3, TriggerOutSelectGPO0_GND, TriggerOutSelectGPO0_NotBypassFrontGPI0, TriggerOutSelectGPO0_NotBypassFrontGPI1, TriggerOutSelectGPO0_NotBypassFrontGPI2, TriggerOutSelectGPO0_NotBypassFrontGPI3, TriggerOutSelectGPO0_NotBypassGPI0, TriggerOutSelectGPO0_NotBypassGPI1, TriggerOutSelectGPO0_NotBypassGPI2, TriggerOutSelectGPO0_NotBypassGPI3, TriggerOutSelectGPO0_NotBypassGPI4, TriggerOutSelectGPO0_NotBypassGPI5, TriggerOutSelectGPO0_NotBypassGPI6, TriggerOutSelectGPO0_NotBypassGPI7, TriggerOutSelectGPO0_NotCamAPulseGenerator0, TriggerOutSelectGPO0_NotCamAPulseGenerator1, TriggerOutSelectGPO0_NotCamAPulseGenerator2, TriggerOutSelectGPO0_NotCamAPulseGenerator3, TriggerOutSelectGPO0_NotCamBPulseGenerator0, TriggerOutSelectGPO0_NotCamBPulseGenerator1, TriggerOutSelectGPO0_NotCamBPulseGenerator2, TriggerOutSelectGPO0_NotCamBPulseGenerator3, TriggerOutSelectGPO0_NotCamCPulseGenerator0, TriggerOutSelectGPO0_NotCamCPulseGenerator1, TriggerOutSelectGPO0_NotCamCPulseGenerator2, TriggerOutSelectGPO0_NotCamCPulseGenerator3, TriggerOutSelectGPO0_NotCamDPulseGenerator0, TriggerOutSelectGPO0_NotCamDPulseGenerator1, TriggerOutSelectGPO0_NotCamDPulseGenerator2, TriggerOutSelectGPO0_NotCamDPulseGenerator3, TriggerOutSelectGPO0_NotPulseGenerator0, TriggerOutSelectGPO0_NotPulseGenerator1, TriggerOutSelectGPO0_NotPulseGenerator2, TriggerOutSelectGPO0_NotPulseGenerator3, TriggerOutSelectGPO0_PulseGenerator0, TriggerOutSelectGPO0_PulseGenerator1, TriggerOutSelectGPO0_PulseGenerator2, TriggerOutSelectGPO0_PulseGenerator3, TriggerOutSelectGPO0_VCC} Valid values for TriggerOutSelectGPO0. |
enum | TriggerOutSelectGPO1Enums { TriggerOutSelectGPO1_BypassFrontGPI0, TriggerOutSelectGPO1_BypassFrontGPI1, TriggerOutSelectGPO1_BypassFrontGPI2, TriggerOutSelectGPO1_BypassFrontGPI3, TriggerOutSelectGPO1_BypassGPI0, TriggerOutSelectGPO1_BypassGPI1, TriggerOutSelectGPO1_BypassGPI2, TriggerOutSelectGPO1_BypassGPI3, TriggerOutSelectGPO1_BypassGPI4, TriggerOutSelectGPO1_BypassGPI5, TriggerOutSelectGPO1_BypassGPI6, TriggerOutSelectGPO1_BypassGPI7, TriggerOutSelectGPO1_CamAPulseGenerator0, TriggerOutSelectGPO1_CamAPulseGenerator1, TriggerOutSelectGPO1_CamAPulseGenerator2, TriggerOutSelectGPO1_CamAPulseGenerator3, TriggerOutSelectGPO1_CamBPulseGenerator0, TriggerOutSelectGPO1_CamBPulseGenerator1, TriggerOutSelectGPO1_CamBPulseGenerator2, TriggerOutSelectGPO1_CamBPulseGenerator3, TriggerOutSelectGPO1_CamCPulseGenerator0, TriggerOutSelectGPO1_CamCPulseGenerator1, TriggerOutSelectGPO1_CamCPulseGenerator2, TriggerOutSelectGPO1_CamCPulseGenerator3, TriggerOutSelectGPO1_CamDPulseGenerator0, TriggerOutSelectGPO1_CamDPulseGenerator1, TriggerOutSelectGPO1_CamDPulseGenerator2, TriggerOutSelectGPO1_CamDPulseGenerator3, TriggerOutSelectGPO1_GND, TriggerOutSelectGPO1_NotBypassFrontGPI0, TriggerOutSelectGPO1_NotBypassFrontGPI1, TriggerOutSelectGPO1_NotBypassFrontGPI2, TriggerOutSelectGPO1_NotBypassFrontGPI3, TriggerOutSelectGPO1_NotBypassGPI0, TriggerOutSelectGPO1_NotBypassGPI1, TriggerOutSelectGPO1_NotBypassGPI2, TriggerOutSelectGPO1_NotBypassGPI3, TriggerOutSelectGPO1_NotBypassGPI4, TriggerOutSelectGPO1_NotBypassGPI5, TriggerOutSelectGPO1_NotBypassGPI6, TriggerOutSelectGPO1_NotBypassGPI7, TriggerOutSelectGPO1_NotCamAPulseGenerator0, TriggerOutSelectGPO1_NotCamAPulseGenerator1, TriggerOutSelectGPO1_NotCamAPulseGenerator2, TriggerOutSelectGPO1_NotCamAPulseGenerator3, TriggerOutSelectGPO1_NotCamBPulseGenerator0, TriggerOutSelectGPO1_NotCamBPulseGenerator1, TriggerOutSelectGPO1_NotCamBPulseGenerator2, TriggerOutSelectGPO1_NotCamBPulseGenerator3, TriggerOutSelectGPO1_NotCamCPulseGenerator0, TriggerOutSelectGPO1_NotCamCPulseGenerator1, TriggerOutSelectGPO1_NotCamCPulseGenerator2, TriggerOutSelectGPO1_NotCamCPulseGenerator3, TriggerOutSelectGPO1_NotCamDPulseGenerator0, TriggerOutSelectGPO1_NotCamDPulseGenerator1, TriggerOutSelectGPO1_NotCamDPulseGenerator2, TriggerOutSelectGPO1_NotCamDPulseGenerator3, TriggerOutSelectGPO1_NotPulseGenerator0, TriggerOutSelectGPO1_NotPulseGenerator1, TriggerOutSelectGPO1_NotPulseGenerator2, TriggerOutSelectGPO1_NotPulseGenerator3, TriggerOutSelectGPO1_PulseGenerator0, TriggerOutSelectGPO1_PulseGenerator1, TriggerOutSelectGPO1_PulseGenerator2, TriggerOutSelectGPO1_PulseGenerator3, TriggerOutSelectGPO1_VCC} Valid values for TriggerOutSelectGPO1. |
enum | TriggerOutSelectGPO2Enums { TriggerOutSelectGPO2_BypassFrontGPI0, TriggerOutSelectGPO2_BypassFrontGPI1, TriggerOutSelectGPO2_BypassFrontGPI2, TriggerOutSelectGPO2_BypassFrontGPI3, TriggerOutSelectGPO2_BypassGPI0, TriggerOutSelectGPO2_BypassGPI1, TriggerOutSelectGPO2_BypassGPI2, TriggerOutSelectGPO2_BypassGPI3, TriggerOutSelectGPO2_BypassGPI4, TriggerOutSelectGPO2_BypassGPI5, TriggerOutSelectGPO2_BypassGPI6, TriggerOutSelectGPO2_BypassGPI7, TriggerOutSelectGPO2_CamAPulseGenerator0, TriggerOutSelectGPO2_CamAPulseGenerator1, TriggerOutSelectGPO2_CamAPulseGenerator2, TriggerOutSelectGPO2_CamAPulseGenerator3, TriggerOutSelectGPO2_CamBPulseGenerator0, TriggerOutSelectGPO2_CamBPulseGenerator1, TriggerOutSelectGPO2_CamBPulseGenerator2, TriggerOutSelectGPO2_CamBPulseGenerator3, TriggerOutSelectGPO2_CamCPulseGenerator0, TriggerOutSelectGPO2_CamCPulseGenerator1, TriggerOutSelectGPO2_CamCPulseGenerator2, TriggerOutSelectGPO2_CamCPulseGenerator3, TriggerOutSelectGPO2_CamDPulseGenerator0, TriggerOutSelectGPO2_CamDPulseGenerator1, TriggerOutSelectGPO2_CamDPulseGenerator2, TriggerOutSelectGPO2_CamDPulseGenerator3, TriggerOutSelectGPO2_GND, TriggerOutSelectGPO2_NotBypassFrontGPI0, TriggerOutSelectGPO2_NotBypassFrontGPI1, TriggerOutSelectGPO2_NotBypassFrontGPI2, TriggerOutSelectGPO2_NotBypassFrontGPI3, TriggerOutSelectGPO2_NotBypassGPI0, TriggerOutSelectGPO2_NotBypassGPI1, TriggerOutSelectGPO2_NotBypassGPI2, TriggerOutSelectGPO2_NotBypassGPI3, TriggerOutSelectGPO2_NotBypassGPI4, TriggerOutSelectGPO2_NotBypassGPI5, TriggerOutSelectGPO2_NotBypassGPI6, TriggerOutSelectGPO2_NotBypassGPI7, TriggerOutSelectGPO2_NotCamAPulseGenerator0, TriggerOutSelectGPO2_NotCamAPulseGenerator1, TriggerOutSelectGPO2_NotCamAPulseGenerator2, TriggerOutSelectGPO2_NotCamAPulseGenerator3, TriggerOutSelectGPO2_NotCamBPulseGenerator0, TriggerOutSelectGPO2_NotCamBPulseGenerator1, TriggerOutSelectGPO2_NotCamBPulseGenerator2, TriggerOutSelectGPO2_NotCamBPulseGenerator3, TriggerOutSelectGPO2_NotCamCPulseGenerator0, TriggerOutSelectGPO2_NotCamCPulseGenerator1, TriggerOutSelectGPO2_NotCamCPulseGenerator2, TriggerOutSelectGPO2_NotCamCPulseGenerator3, TriggerOutSelectGPO2_NotCamDPulseGenerator0, TriggerOutSelectGPO2_NotCamDPulseGenerator1, TriggerOutSelectGPO2_NotCamDPulseGenerator2, TriggerOutSelectGPO2_NotCamDPulseGenerator3, TriggerOutSelectGPO2_NotPulseGenerator0, TriggerOutSelectGPO2_NotPulseGenerator1, TriggerOutSelectGPO2_NotPulseGenerator2, TriggerOutSelectGPO2_NotPulseGenerator3, TriggerOutSelectGPO2_PulseGenerator0, TriggerOutSelectGPO2_PulseGenerator1, TriggerOutSelectGPO2_PulseGenerator2, TriggerOutSelectGPO2_PulseGenerator3, TriggerOutSelectGPO2_VCC} Valid values for TriggerOutSelectGPO2. |
enum | TriggerOutSelectGPO3Enums { TriggerOutSelectGPO3_BypassFrontGPI0, TriggerOutSelectGPO3_BypassFrontGPI1, TriggerOutSelectGPO3_BypassFrontGPI2, TriggerOutSelectGPO3_BypassFrontGPI3, TriggerOutSelectGPO3_BypassGPI0, TriggerOutSelectGPO3_BypassGPI1, TriggerOutSelectGPO3_BypassGPI2, TriggerOutSelectGPO3_BypassGPI3, TriggerOutSelectGPO3_BypassGPI4, TriggerOutSelectGPO3_BypassGPI5, TriggerOutSelectGPO3_BypassGPI6, TriggerOutSelectGPO3_BypassGPI7, TriggerOutSelectGPO3_CamAPulseGenerator0, TriggerOutSelectGPO3_CamAPulseGenerator1, TriggerOutSelectGPO3_CamAPulseGenerator2, TriggerOutSelectGPO3_CamAPulseGenerator3, TriggerOutSelectGPO3_CamBPulseGenerator0, TriggerOutSelectGPO3_CamBPulseGenerator1, TriggerOutSelectGPO3_CamBPulseGenerator2, TriggerOutSelectGPO3_CamBPulseGenerator3, TriggerOutSelectGPO3_CamCPulseGenerator0, TriggerOutSelectGPO3_CamCPulseGenerator1, TriggerOutSelectGPO3_CamCPulseGenerator2, TriggerOutSelectGPO3_CamCPulseGenerator3, TriggerOutSelectGPO3_CamDPulseGenerator0, TriggerOutSelectGPO3_CamDPulseGenerator1, TriggerOutSelectGPO3_CamDPulseGenerator2, TriggerOutSelectGPO3_CamDPulseGenerator3, TriggerOutSelectGPO3_GND, TriggerOutSelectGPO3_NotBypassFrontGPI0, TriggerOutSelectGPO3_NotBypassFrontGPI1, TriggerOutSelectGPO3_NotBypassFrontGPI2, TriggerOutSelectGPO3_NotBypassFrontGPI3, TriggerOutSelectGPO3_NotBypassGPI0, TriggerOutSelectGPO3_NotBypassGPI1, TriggerOutSelectGPO3_NotBypassGPI2, TriggerOutSelectGPO3_NotBypassGPI3, TriggerOutSelectGPO3_NotBypassGPI4, TriggerOutSelectGPO3_NotBypassGPI5, TriggerOutSelectGPO3_NotBypassGPI6, TriggerOutSelectGPO3_NotBypassGPI7, TriggerOutSelectGPO3_NotCamAPulseGenerator0, TriggerOutSelectGPO3_NotCamAPulseGenerator1, TriggerOutSelectGPO3_NotCamAPulseGenerator2, TriggerOutSelectGPO3_NotCamAPulseGenerator3, TriggerOutSelectGPO3_NotCamBPulseGenerator0, TriggerOutSelectGPO3_NotCamBPulseGenerator1, TriggerOutSelectGPO3_NotCamBPulseGenerator2, TriggerOutSelectGPO3_NotCamBPulseGenerator3, TriggerOutSelectGPO3_NotCamCPulseGenerator0, TriggerOutSelectGPO3_NotCamCPulseGenerator1, TriggerOutSelectGPO3_NotCamCPulseGenerator2, TriggerOutSelectGPO3_NotCamCPulseGenerator3, TriggerOutSelectGPO3_NotCamDPulseGenerator0, TriggerOutSelectGPO3_NotCamDPulseGenerator1, TriggerOutSelectGPO3_NotCamDPulseGenerator2, TriggerOutSelectGPO3_NotCamDPulseGenerator3, TriggerOutSelectGPO3_NotPulseGenerator0, TriggerOutSelectGPO3_NotPulseGenerator1, TriggerOutSelectGPO3_NotPulseGenerator2, TriggerOutSelectGPO3_NotPulseGenerator3, TriggerOutSelectGPO3_PulseGenerator0, TriggerOutSelectGPO3_PulseGenerator1, TriggerOutSelectGPO3_PulseGenerator2, TriggerOutSelectGPO3_PulseGenerator3, TriggerOutSelectGPO3_VCC} Valid values for TriggerOutSelectGPO3. |
enum | TriggerOutSelectGPO4Enums { TriggerOutSelectGPO4_BypassFrontGPI0, TriggerOutSelectGPO4_BypassFrontGPI1, TriggerOutSelectGPO4_BypassFrontGPI2, TriggerOutSelectGPO4_BypassFrontGPI3, TriggerOutSelectGPO4_BypassGPI0, TriggerOutSelectGPO4_BypassGPI1, TriggerOutSelectGPO4_BypassGPI2, TriggerOutSelectGPO4_BypassGPI3, TriggerOutSelectGPO4_BypassGPI4, TriggerOutSelectGPO4_BypassGPI5, TriggerOutSelectGPO4_BypassGPI6, TriggerOutSelectGPO4_BypassGPI7, TriggerOutSelectGPO4_CamAPulseGenerator0, TriggerOutSelectGPO4_CamAPulseGenerator1, TriggerOutSelectGPO4_CamAPulseGenerator2, TriggerOutSelectGPO4_CamAPulseGenerator3, TriggerOutSelectGPO4_CamBPulseGenerator0, TriggerOutSelectGPO4_CamBPulseGenerator1, TriggerOutSelectGPO4_CamBPulseGenerator2, TriggerOutSelectGPO4_CamBPulseGenerator3, TriggerOutSelectGPO4_CamCPulseGenerator0, TriggerOutSelectGPO4_CamCPulseGenerator1, TriggerOutSelectGPO4_CamCPulseGenerator2, TriggerOutSelectGPO4_CamCPulseGenerator3, TriggerOutSelectGPO4_CamDPulseGenerator0, TriggerOutSelectGPO4_CamDPulseGenerator1, TriggerOutSelectGPO4_CamDPulseGenerator2, TriggerOutSelectGPO4_CamDPulseGenerator3, TriggerOutSelectGPO4_GND, TriggerOutSelectGPO4_NotBypassFrontGPI0, TriggerOutSelectGPO4_NotBypassFrontGPI1, TriggerOutSelectGPO4_NotBypassFrontGPI2, TriggerOutSelectGPO4_NotBypassFrontGPI3, TriggerOutSelectGPO4_NotBypassGPI0, TriggerOutSelectGPO4_NotBypassGPI1, TriggerOutSelectGPO4_NotBypassGPI2, TriggerOutSelectGPO4_NotBypassGPI3, TriggerOutSelectGPO4_NotBypassGPI4, TriggerOutSelectGPO4_NotBypassGPI5, TriggerOutSelectGPO4_NotBypassGPI6, TriggerOutSelectGPO4_NotBypassGPI7, TriggerOutSelectGPO4_NotCamAPulseGenerator0, TriggerOutSelectGPO4_NotCamAPulseGenerator1, TriggerOutSelectGPO4_NotCamAPulseGenerator2, TriggerOutSelectGPO4_NotCamAPulseGenerator3, TriggerOutSelectGPO4_NotCamBPulseGenerator0, TriggerOutSelectGPO4_NotCamBPulseGenerator1, TriggerOutSelectGPO4_NotCamBPulseGenerator2, TriggerOutSelectGPO4_NotCamBPulseGenerator3, TriggerOutSelectGPO4_NotCamCPulseGenerator0, TriggerOutSelectGPO4_NotCamCPulseGenerator1, TriggerOutSelectGPO4_NotCamCPulseGenerator2, TriggerOutSelectGPO4_NotCamCPulseGenerator3, TriggerOutSelectGPO4_NotCamDPulseGenerator0, TriggerOutSelectGPO4_NotCamDPulseGenerator1, TriggerOutSelectGPO4_NotCamDPulseGenerator2, TriggerOutSelectGPO4_NotCamDPulseGenerator3, TriggerOutSelectGPO4_NotPulseGenerator0, TriggerOutSelectGPO4_NotPulseGenerator1, TriggerOutSelectGPO4_NotPulseGenerator2, TriggerOutSelectGPO4_NotPulseGenerator3, TriggerOutSelectGPO4_PulseGenerator0, TriggerOutSelectGPO4_PulseGenerator1, TriggerOutSelectGPO4_PulseGenerator2, TriggerOutSelectGPO4_PulseGenerator3, TriggerOutSelectGPO4_VCC} Valid values for TriggerOutSelectGPO4. |
enum | TriggerOutSelectGPO5Enums { TriggerOutSelectGPO5_BypassFrontGPI0, TriggerOutSelectGPO5_BypassFrontGPI1, TriggerOutSelectGPO5_BypassFrontGPI2, TriggerOutSelectGPO5_BypassFrontGPI3, TriggerOutSelectGPO5_BypassGPI0, TriggerOutSelectGPO5_BypassGPI1, TriggerOutSelectGPO5_BypassGPI2, TriggerOutSelectGPO5_BypassGPI3, TriggerOutSelectGPO5_BypassGPI4, TriggerOutSelectGPO5_BypassGPI5, TriggerOutSelectGPO5_BypassGPI6, TriggerOutSelectGPO5_BypassGPI7, TriggerOutSelectGPO5_CamAPulseGenerator0, TriggerOutSelectGPO5_CamAPulseGenerator1, TriggerOutSelectGPO5_CamAPulseGenerator2, TriggerOutSelectGPO5_CamAPulseGenerator3, TriggerOutSelectGPO5_CamBPulseGenerator0, TriggerOutSelectGPO5_CamBPulseGenerator1, TriggerOutSelectGPO5_CamBPulseGenerator2, TriggerOutSelectGPO5_CamBPulseGenerator3, TriggerOutSelectGPO5_CamCPulseGenerator0, TriggerOutSelectGPO5_CamCPulseGenerator1, TriggerOutSelectGPO5_CamCPulseGenerator2, TriggerOutSelectGPO5_CamCPulseGenerator3, TriggerOutSelectGPO5_CamDPulseGenerator0, TriggerOutSelectGPO5_CamDPulseGenerator1, TriggerOutSelectGPO5_CamDPulseGenerator2, TriggerOutSelectGPO5_CamDPulseGenerator3, TriggerOutSelectGPO5_GND, TriggerOutSelectGPO5_NotBypassFrontGPI0, TriggerOutSelectGPO5_NotBypassFrontGPI1, TriggerOutSelectGPO5_NotBypassFrontGPI2, TriggerOutSelectGPO5_NotBypassFrontGPI3, TriggerOutSelectGPO5_NotBypassGPI0, TriggerOutSelectGPO5_NotBypassGPI1, TriggerOutSelectGPO5_NotBypassGPI2, TriggerOutSelectGPO5_NotBypassGPI3, TriggerOutSelectGPO5_NotBypassGPI4, TriggerOutSelectGPO5_NotBypassGPI5, TriggerOutSelectGPO5_NotBypassGPI6, TriggerOutSelectGPO5_NotBypassGPI7, TriggerOutSelectGPO5_NotCamAPulseGenerator0, TriggerOutSelectGPO5_NotCamAPulseGenerator1, TriggerOutSelectGPO5_NotCamAPulseGenerator2, TriggerOutSelectGPO5_NotCamAPulseGenerator3, TriggerOutSelectGPO5_NotCamBPulseGenerator0, TriggerOutSelectGPO5_NotCamBPulseGenerator1, TriggerOutSelectGPO5_NotCamBPulseGenerator2, TriggerOutSelectGPO5_NotCamBPulseGenerator3, TriggerOutSelectGPO5_NotCamCPulseGenerator0, TriggerOutSelectGPO5_NotCamCPulseGenerator1, TriggerOutSelectGPO5_NotCamCPulseGenerator2, TriggerOutSelectGPO5_NotCamCPulseGenerator3, TriggerOutSelectGPO5_NotCamDPulseGenerator0, TriggerOutSelectGPO5_NotCamDPulseGenerator1, TriggerOutSelectGPO5_NotCamDPulseGenerator2, TriggerOutSelectGPO5_NotCamDPulseGenerator3, TriggerOutSelectGPO5_NotPulseGenerator0, TriggerOutSelectGPO5_NotPulseGenerator1, TriggerOutSelectGPO5_NotPulseGenerator2, TriggerOutSelectGPO5_NotPulseGenerator3, TriggerOutSelectGPO5_PulseGenerator0, TriggerOutSelectGPO5_PulseGenerator1, TriggerOutSelectGPO5_PulseGenerator2, TriggerOutSelectGPO5_PulseGenerator3, TriggerOutSelectGPO5_VCC} Valid values for TriggerOutSelectGPO5. |
enum | TriggerOutSelectGPO6Enums { TriggerOutSelectGPO6_BypassFrontGPI0, TriggerOutSelectGPO6_BypassFrontGPI1, TriggerOutSelectGPO6_BypassFrontGPI2, TriggerOutSelectGPO6_BypassFrontGPI3, TriggerOutSelectGPO6_BypassGPI0, TriggerOutSelectGPO6_BypassGPI1, TriggerOutSelectGPO6_BypassGPI2, TriggerOutSelectGPO6_BypassGPI3, TriggerOutSelectGPO6_BypassGPI4, TriggerOutSelectGPO6_BypassGPI5, TriggerOutSelectGPO6_BypassGPI6, TriggerOutSelectGPO6_BypassGPI7, TriggerOutSelectGPO6_CamAPulseGenerator0, TriggerOutSelectGPO6_CamAPulseGenerator1, TriggerOutSelectGPO6_CamAPulseGenerator2, TriggerOutSelectGPO6_CamAPulseGenerator3, TriggerOutSelectGPO6_CamBPulseGenerator0, TriggerOutSelectGPO6_CamBPulseGenerator1, TriggerOutSelectGPO6_CamBPulseGenerator2, TriggerOutSelectGPO6_CamBPulseGenerator3, TriggerOutSelectGPO6_CamCPulseGenerator0, TriggerOutSelectGPO6_CamCPulseGenerator1, TriggerOutSelectGPO6_CamCPulseGenerator2, TriggerOutSelectGPO6_CamCPulseGenerator3, TriggerOutSelectGPO6_CamDPulseGenerator0, TriggerOutSelectGPO6_CamDPulseGenerator1, TriggerOutSelectGPO6_CamDPulseGenerator2, TriggerOutSelectGPO6_CamDPulseGenerator3, TriggerOutSelectGPO6_GND, TriggerOutSelectGPO6_NotBypassFrontGPI0, TriggerOutSelectGPO6_NotBypassFrontGPI1, TriggerOutSelectGPO6_NotBypassFrontGPI2, TriggerOutSelectGPO6_NotBypassFrontGPI3, TriggerOutSelectGPO6_NotBypassGPI0, TriggerOutSelectGPO6_NotBypassGPI1, TriggerOutSelectGPO6_NotBypassGPI2, TriggerOutSelectGPO6_NotBypassGPI3, TriggerOutSelectGPO6_NotBypassGPI4, TriggerOutSelectGPO6_NotBypassGPI5, TriggerOutSelectGPO6_NotBypassGPI6, TriggerOutSelectGPO6_NotBypassGPI7, TriggerOutSelectGPO6_NotCamAPulseGenerator0, TriggerOutSelectGPO6_NotCamAPulseGenerator1, TriggerOutSelectGPO6_NotCamAPulseGenerator2, TriggerOutSelectGPO6_NotCamAPulseGenerator3, TriggerOutSelectGPO6_NotCamBPulseGenerator0, TriggerOutSelectGPO6_NotCamBPulseGenerator1, TriggerOutSelectGPO6_NotCamBPulseGenerator2, TriggerOutSelectGPO6_NotCamBPulseGenerator3, TriggerOutSelectGPO6_NotCamCPulseGenerator0, TriggerOutSelectGPO6_NotCamCPulseGenerator1, TriggerOutSelectGPO6_NotCamCPulseGenerator2, TriggerOutSelectGPO6_NotCamCPulseGenerator3, TriggerOutSelectGPO6_NotCamDPulseGenerator0, TriggerOutSelectGPO6_NotCamDPulseGenerator1, TriggerOutSelectGPO6_NotCamDPulseGenerator2, TriggerOutSelectGPO6_NotCamDPulseGenerator3, TriggerOutSelectGPO6_NotPulseGenerator0, TriggerOutSelectGPO6_NotPulseGenerator1, TriggerOutSelectGPO6_NotPulseGenerator2, TriggerOutSelectGPO6_NotPulseGenerator3, TriggerOutSelectGPO6_PulseGenerator0, TriggerOutSelectGPO6_PulseGenerator1, TriggerOutSelectGPO6_PulseGenerator2, TriggerOutSelectGPO6_PulseGenerator3, TriggerOutSelectGPO6_VCC} Valid values for TriggerOutSelectGPO6. |
enum | TriggerOutSelectGPO7Enums { TriggerOutSelectGPO7_BypassFrontGPI0, TriggerOutSelectGPO7_BypassFrontGPI1, TriggerOutSelectGPO7_BypassFrontGPI2, TriggerOutSelectGPO7_BypassFrontGPI3, TriggerOutSelectGPO7_BypassGPI0, TriggerOutSelectGPO7_BypassGPI1, TriggerOutSelectGPO7_BypassGPI2, TriggerOutSelectGPO7_BypassGPI3, TriggerOutSelectGPO7_BypassGPI4, TriggerOutSelectGPO7_BypassGPI5, TriggerOutSelectGPO7_BypassGPI6, TriggerOutSelectGPO7_BypassGPI7, TriggerOutSelectGPO7_CamAPulseGenerator0, TriggerOutSelectGPO7_CamAPulseGenerator1, TriggerOutSelectGPO7_CamAPulseGenerator2, TriggerOutSelectGPO7_CamAPulseGenerator3, TriggerOutSelectGPO7_CamBPulseGenerator0, TriggerOutSelectGPO7_CamBPulseGenerator1, TriggerOutSelectGPO7_CamBPulseGenerator2, TriggerOutSelectGPO7_CamBPulseGenerator3, TriggerOutSelectGPO7_CamCPulseGenerator0, TriggerOutSelectGPO7_CamCPulseGenerator1, TriggerOutSelectGPO7_CamCPulseGenerator2, TriggerOutSelectGPO7_CamCPulseGenerator3, TriggerOutSelectGPO7_CamDPulseGenerator0, TriggerOutSelectGPO7_CamDPulseGenerator1, TriggerOutSelectGPO7_CamDPulseGenerator2, TriggerOutSelectGPO7_CamDPulseGenerator3, TriggerOutSelectGPO7_GND, TriggerOutSelectGPO7_NotBypassFrontGPI0, TriggerOutSelectGPO7_NotBypassFrontGPI1, TriggerOutSelectGPO7_NotBypassFrontGPI2, TriggerOutSelectGPO7_NotBypassFrontGPI3, TriggerOutSelectGPO7_NotBypassGPI0, TriggerOutSelectGPO7_NotBypassGPI1, TriggerOutSelectGPO7_NotBypassGPI2, TriggerOutSelectGPO7_NotBypassGPI3, TriggerOutSelectGPO7_NotBypassGPI4, TriggerOutSelectGPO7_NotBypassGPI5, TriggerOutSelectGPO7_NotBypassGPI6, TriggerOutSelectGPO7_NotBypassGPI7, TriggerOutSelectGPO7_NotCamAPulseGenerator0, TriggerOutSelectGPO7_NotCamAPulseGenerator1, TriggerOutSelectGPO7_NotCamAPulseGenerator2, TriggerOutSelectGPO7_NotCamAPulseGenerator3, TriggerOutSelectGPO7_NotCamBPulseGenerator0, TriggerOutSelectGPO7_NotCamBPulseGenerator1, TriggerOutSelectGPO7_NotCamBPulseGenerator2, TriggerOutSelectGPO7_NotCamBPulseGenerator3, TriggerOutSelectGPO7_NotCamCPulseGenerator0, TriggerOutSelectGPO7_NotCamCPulseGenerator1, TriggerOutSelectGPO7_NotCamCPulseGenerator2, TriggerOutSelectGPO7_NotCamCPulseGenerator3, TriggerOutSelectGPO7_NotCamDPulseGenerator0, TriggerOutSelectGPO7_NotCamDPulseGenerator1, TriggerOutSelectGPO7_NotCamDPulseGenerator2, TriggerOutSelectGPO7_NotCamDPulseGenerator3, TriggerOutSelectGPO7_NotPulseGenerator0, TriggerOutSelectGPO7_NotPulseGenerator1, TriggerOutSelectGPO7_NotPulseGenerator2, TriggerOutSelectGPO7_NotPulseGenerator3, TriggerOutSelectGPO7_PulseGenerator0, TriggerOutSelectGPO7_PulseGenerator1, TriggerOutSelectGPO7_PulseGenerator2, TriggerOutSelectGPO7_PulseGenerator3, TriggerOutSelectGPO7_VCC} Valid values for TriggerOutSelectGPO7. |
enum | TriggerOutStatisticsSourceEnums { TriggerOutStatisticsSource_PulseGenerator0, TriggerOutStatisticsSource_PulseGenerator1, TriggerOutStatisticsSource_PulseGenerator2, TriggerOutStatisticsSource_PulseGenerator3} Valid values for TriggerOutStatisticsSource. |
enum | TriggerOutputEventSelectEnums { TriggerOutputEventSelect_PulseGenerator0, TriggerOutputEventSelect_PulseGenerator1, TriggerOutputEventSelect_PulseGenerator2, TriggerOutputEventSelect_PulseGenerator3} Valid values for TriggerOutputEventSelect. |
enum | TriggerQueueModeEnums { TriggerQueueMode_Off, TriggerQueueMode_On} Valid values for TriggerQueueMode. |
enum | TriggerStateEnums { TriggerState_Active, TriggerState_AsyncStop, TriggerState_SyncStop} Valid values for TriggerState. |
enum | VantagePointEnums { VantagePoint_BottomLeft, VantagePoint_BottomRight, VantagePoint_TopLeft, VantagePoint_TopRight} Valid values for VantagePoint. |
Types Documentation#
enum AreaTriggerModeEnums#
Enumerator | Value | Description |
---|---|---|
AreaTriggerMode_External | The trigger mode is set to External - Applies to: CoaXPress. | |
AreaTriggerMode_Generator | The trigger mode is set to Generator - Applies to: CoaXPress. | |
AreaTriggerMode_Software | The trigger mode is set to Software - Applies to: CoaXPress. | |
AreaTriggerMode_Synchronized | The trigger mode is set to Synchronized - Applies to: CoaXPress. |
enum BitAlignmentEnums#
Enumerator | Value | Description |
---|---|---|
BitAlignment_CustomBitShift | The bits are shifted by a user-defined value - Applies to: CoaXPress. | |
BitAlignment_LeftAligned | The bits left-aligned - Applies to: CoaXPress. | |
BitAlignment_RightAligned | The bits right-aligned - Applies to: CoaXPress. |
Valid values for BitAlignment.
enum CxpLinkConfigurationEnums#
Enumerator | Value | Description |
---|---|---|
CxpLinkConfiguration_Auto | Link speed is controlled automatically - Applies to: CoaXPress. | |
CxpLinkConfiguration_CXP10_X1 | 1 connection is operating at CXP-10 speed (10 0 Gbps) - Applies to: CoaXPress | |
CxpLinkConfiguration_CXP10_X2 | 2 connections are operating at CXP-10 speed (10 0 Gbps) - Applies to: CoaXPress | |
CxpLinkConfiguration_CXP10_X3 | 3 connections are operating at CXP-10 speed (10 0 Gbps) - Applies to: CoaXPress | |
CxpLinkConfiguration_CXP10_X4 | 4 connections are operating at CXP-10 speed (10 0 Gbps) - Applies to: CoaXPress | |
CxpLinkConfiguration_CXP12_X1 | 1 connection is operating at CXP-12 speed (12 50 Gbps) - Applies to: CoaXPress | |
CxpLinkConfiguration_CXP12_X2 | 2 connections are operating at CXP-12 speed (12 50 Gbps) - Applies to: CoaXPress | |
CxpLinkConfiguration_CXP12_X3 | 3 connections are operating at CXP-12 speed (12 50 Gbps) - Applies to: CoaXPress | |
CxpLinkConfiguration_CXP12_X4 | 4 connections are operating at CXP-12 speed (12 50 Gbps) - Applies to: CoaXPress | |
CxpLinkConfiguration_CXP1_X1 | 1 connection is operating at CXP-1 speed (1 25 Gbps) - Applies to: CoaXPress | |
CxpLinkConfiguration_CXP1_X2 | 2 connections are operating at CXP-1 speed (1 25 Gbps) - Applies to: CoaXPress | |
CxpLinkConfiguration_CXP1_X3 | 3 connections are operating at CXP-1 speed (1 25 Gbps) - Applies to: CoaXPress | |
CxpLinkConfiguration_CXP1_X4 | 4 connections are operating at CXP-1 speed (1 25 Gbps) - Applies to: CoaXPress | |
CxpLinkConfiguration_CXP2_X1 | 1 connection is operating at CXP-2 speed (2 50 Gbps) - Applies to: CoaXPress | |
CxpLinkConfiguration_CXP2_X2 | 2 connections are operating at CXP-2 speed (2 50 Gbps) - Applies to: CoaXPress | |
CxpLinkConfiguration_CXP2_X3 | 3 connections are operating at CXP-2 speed (2 50 Gbps) - Applies to: CoaXPress | |
CxpLinkConfiguration_CXP2_X4 | 4 connections are operating at CXP-2 speed (2 50 Gbps) - Applies to: CoaXPress | |
CxpLinkConfiguration_CXP3_X1 | 1 connection is operating at CXP-3 speed (3 125 Gbps) - Applies to: CoaXPress | |
CxpLinkConfiguration_CXP3_X2 | 2 connections are operating at CXP-3 speed (3 125 Gbps) - Applies to: CoaXPress | |
CxpLinkConfiguration_CXP3_X3 | 3 connections are operating at CXP-3 speed (3 125 Gbps) - Applies to: CoaXPress | |
CxpLinkConfiguration_CXP3_X4 | 4 connections are operating at CXP-3 speed (3 125 Gbps) - Applies to: CoaXPress | |
CxpLinkConfiguration_CXP5_X1 | 1 connection is operating at CXP-5 speed (5 00 Gbps) - Applies to: CoaXPress | |
CxpLinkConfiguration_CXP5_X2 | 2 connections are operating at CXP-5 speed (5 00 Gbps) - Applies to: CoaXPress | |
CxpLinkConfiguration_CXP5_X3 | 3 connections are operating at CXP-5 speed (5 00 Gbps) - Applies to: CoaXPress | |
CxpLinkConfiguration_CXP5_X4 | 4 connections are operating at CXP-5 speed (5 00 Gbps) - Applies to: CoaXPress | |
CxpLinkConfiguration_CXP6_X1 | 1 connection is operating at CXP-6 speed (6 25 Gbps) - Applies to: CoaXPress | |
CxpLinkConfiguration_CXP6_X2 | 2 connections are operating at CXP-6 speed (6 25 Gbps) - Applies to: CoaXPress | |
CxpLinkConfiguration_CXP6_X3 | 3 connections are operating at CXP-6 speed (6 25 Gbps) - Applies to: CoaXPress | |
CxpLinkConfiguration_CXP6_X4 | 4 connections are operating at CXP-6 speed (6 25 Gbps) - Applies to: CoaXPress |
Valid values for CxpLinkConfiguration.
enum CxpTriggerPacketModeEnums#
Enumerator | Value | Description |
---|---|---|
CxpTriggerPacketMode_CXPTriggerRising | Only rising edge trigger packets are sent - Applies to: CoaXPress. | |
CxpTriggerPacketMode_CXPTriggerStandard | Rising and falling edge trigger packets are sent on an alternating basis - Applies to: CoaXPress. |
Valid values for CxpTriggerPacketMode.
enum DeviceAccessStatusEnums#
Enumerator | Value | Description |
---|---|---|
DeviceAccessStatus_Busy | The device is already opened by another entity - Applies to: CoaXPress and blaze. | |
DeviceAccessStatus_NoAccess | You can't connect to the device - Applies to: CoaXPress and blaze. | |
DeviceAccessStatus_OpenReadOnly | The device is opened in Read-only mode by this GenTL host - Applies to: CoaXPress and blaze. | |
DeviceAccessStatus_OpenReadWrite | The device is opened in Read/Write mode by this GenTL host - Applies to: CoaXPress and blaze. | |
DeviceAccessStatus_ReadOnly | The device offers read-only access - Applies to: CoaXPress and blaze. | |
DeviceAccessStatus_ReadWrite | The device offers read/write access - Applies to: CoaXPress and blaze. | |
DeviceAccessStatus_Unknown | The status is unknown - Applies to: CoaXPress and blaze. |
Valid values for DeviceAccessStatus.
enum DeviceEndianessMechanismEnums#
Enumerator | Value | Description |
---|---|---|
DeviceEndianessMechanism_Legacy | The device endianness is handled according to GenICam Schema 1 0 - Applies to: blaze. | |
DeviceEndianessMechanism_Standard | The device endianness is handled according to GenICam Schema 1 1 and later - Applies to: blaze. |
Valid values for DeviceEndianessMechanism.
enum DeviceTypeEnums#
Enumerator | Value | Description |
---|---|---|
DeviceType_CL | The device uses the Camera Link transport layer - Applies to: CoaXPress. | |
DeviceType_CLHS | The device uses the Camera Link HS transport layer - Applies to: CoaXPress. | |
DeviceType_CXP | The device uses the CoaXPress transport layer - Applies to: CoaXPress. | |
DeviceType_CameraLink | Camera Link - Applies to: CoaXPress. | |
DeviceType_CameraLinkHS | Camera Link High Speed - Applies to: CoaXPress. | |
DeviceType_CoaXPress | CoaXPress - Applies to: CoaXPress. | |
DeviceType_Custom | The device uses a custom transport layer - Applies to: CoaXPress. | |
DeviceType_GEV | The device uses the GigE Vision transport layer - Applies to: CoaXPress. | |
DeviceType_GigEVision | GigE Vision - Applies to: CoaXPress. | |
DeviceType_Mixed | Different interface modules of the GenTL Producer are of different types - Applies to: CoaXPress. | |
DeviceType_U3V | The device uses the USB3 Vision transport layer - Applies to: CoaXPress. | |
DeviceType_USB3Vision | USB3 Vision - Applies to: CoaXPress. |
Valid values for DeviceType.
enum EventNotificationEnums#
Enumerator | Value | Description |
---|---|---|
EventNotification_Off | The selected event notification is disabled - Applies to: CoaXPress and blaze. | |
EventNotification_On | The selected event notification is enabled - Applies to: CoaXPress and blaze. | |
EventNotification_Once | The selected event notification is enabled for one event and then returned to Off state - Applies to: CoaXPress and blaze. |
Valid values for EventNotification.
enum EventSelectorEnums#
Enumerator | Value | Description |
---|---|---|
EventSelector_AcquisitionTrigger | Entry for the event AcquisitionTrigger - Applies to: CoaXPress. | |
EventSelector_DeviceLost | The Device Lost event is selected - Applies to: CoaXPress and blaze. | |
EventSelector_FrameTransferEnd | Entry for the event FrameTransferEnd - Applies to: CoaXPress. | |
EventSelector_FrameTransferStart | Entry for the event FrameTransferStart - Applies to: CoaXPress. | |
EventSelector_FrameTriggerMissed | Entry for the event FrameTriggerMissed - Applies to: CoaXPress. | |
EventSelector_Overflow | Entry for the event Overflow - Applies to: CoaXPress. | |
EventSelector_TriggerExceededPeriodLimits | Entry for the event TriggerExceededPeriodLimits - Applies to: CoaXPress. | |
EventSelector_TriggerQueueFilllevelThresholdOff | Entry for the event TriggerQueueFilllevelThresholdOff - Applies to: CoaXPress. | |
EventSelector_TriggerQueueFilllevelThresholdOn | Entry for the event TriggerQueueFilllevelThresholdOn - Applies to: CoaXPress. |
Valid values for EventSelector.
enum FormatEnums#
Enumerator | Value | Description |
---|---|---|
Format_BGR10p | The pixel output format is set to BGR10p - Applies to: CoaXPress. | |
Format_BGR12p | The pixel output format is set to BGR12p - Applies to: CoaXPress. | |
Format_BGR14p | The pixel output format is set to BGR14p - Applies to: CoaXPress. | |
Format_BGR16 | The pixel output format is set to BGR16 - Applies to: CoaXPress. | |
Format_BGR8 | The pixel output format is set to BGR8 - Applies to: CoaXPress. | |
Format_BGRa8 | The pixel output format is set to BGRa8 - Applies to: CoaXPress. | |
Format_BayerBG10p | The pixel output format is set to BayerBG10p - Applies to: CoaXPress. | |
Format_BayerBG12p | The pixel output format is set to BayerBG12p - Applies to: CoaXPress. | |
Format_BayerBG14p | The pixel output format is set to BayerBG14p - Applies to: CoaXPress. | |
Format_BayerBG16 | The pixel output format is set to BayerBG16 - Applies to: CoaXPress. | |
Format_BayerBG8 | The pixel output format is set to BayerBG8 - Applies to: CoaXPress. | |
Format_BayerGB10p | The pixel output format is set to BayerGB10p - Applies to: CoaXPress. | |
Format_BayerGB12p | The pixel output format is set to BayerGB12p - Applies to: CoaXPress. | |
Format_BayerGB14p | The pixel output format is set to BayerGB14p - Applies to: CoaXPress. | |
Format_BayerGB16 | The pixel output format is set to BayerGB16 - Applies to: CoaXPress. | |
Format_BayerGB8 | The pixel output format is set to BayerGB8 - Applies to: CoaXPress. | |
Format_BayerGR10p | The pixel output format is set to BayerGR10p - Applies to: CoaXPress. | |
Format_BayerGR12p | The pixel output format is set to BayerGR12p - Applies to: CoaXPress. | |
Format_BayerGR14p | The pixel output format is set to BayerGR14p - Applies to: CoaXPress. | |
Format_BayerGR16 | The pixel output format is set to BayerGR16 - Applies to: CoaXPress. | |
Format_BayerGR8 | The pixel output format is set to BayerGR8 - Applies to: CoaXPress. | |
Format_BayerRG10p | The pixel output format is set to BayerRG10p - Applies to: CoaXPress. | |
Format_BayerRG12p | The pixel output format is set to BayerRG12p - Applies to: CoaXPress. | |
Format_BayerRG14p | The pixel output format is set to BayerRG14p - Applies to: CoaXPress. | |
Format_BayerRG16 | The pixel output format is set to BayerRG16 - Applies to: CoaXPress. | |
Format_BayerRG8 | The pixel output format is set to BayerRG8 - Applies to: CoaXPress. | |
Format_Mono10p | The pixel output format is set to Mono10p - Applies to: CoaXPress. | |
Format_Mono12p | The pixel output format is set to Mono12p - Applies to: CoaXPress. | |
Format_Mono14p | The pixel output format is set to Mono14p - Applies to: CoaXPress. | |
Format_Mono16 | The pixel output format is set to Mono16 - Applies to: CoaXPress. | |
Format_Mono8 | The pixel output format is set to Mono8 - Applies to: CoaXPress. | |
Format_RGB10p | The pixel output format is set to RGB10p - Applies to: CoaXPress. | |
Format_RGB12p | The pixel output format is set to RGB12p - Applies to: CoaXPress. | |
Format_RGB14p | The pixel output format is set to RGB14p - Applies to: CoaXPress. | |
Format_RGB16 | The pixel output format is set to RGB16 - Applies to: CoaXPress. | |
Format_RGB8 | The pixel output format is set to RGB8 - Applies to: CoaXPress. | |
Format_RGBa8 | The pixel output format is set to RGBa8 - Applies to: CoaXPress. | |
Format_YCbCr422_8 | The pixel output format is set to YCbCr422_8 - Applies to: CoaXPress. |
Valid values for Format.
enum LutEnableEnums#
Enumerator | Value | Description |
---|---|---|
LutEnable_Off | The trigger queue mode is disabled - Applies to: CoaXPress. | |
LutEnable_On | The trigger queue mode is enabled - Applies to: CoaXPress. |
Valid values for LutEnable.
enum LutImplementationTypeEnums#
Enumerator | Value | Description |
---|---|---|
LutImplementationType_FullLUT | Defines 1 value for each possible pixel value - Applies to: CoaXPress. | |
LutImplementationType_KneeLUT | Uses an interpolation for pixel values based one a set of defined values - Applies to: CoaXPress. |
Valid values for LutImplementationType.
enum LutTypeEnums#
Enumerator | Value | Description |
---|---|---|
LutType_Processor | Processor - Applies to: CoaXPress. | |
LutType_UserFile | Use a user file to configure the value - Applies to: CoaXPress. |
Valid values for LutType.
enum MissingCameraFrameResponseEnums#
Enumerator | Value | Description |
---|---|---|
MissingCameraFrameResponse_No | The camera sends a frame for each output trigger pulse - Applies to: CoaXPress. | |
MissingCameraFrameResponse_Yes | The camera doesn't send a frame for each output trigger pulse - Applies to: CoaXPress. |
Valid values for MissingCameraFrameResponse.
enum OverflowEventSelectEnums#
Enumerator | Value | Description |
---|---|---|
OverflowEventSelect_All | All - Applies to: CoaXPress. | |
OverflowEventSelect_Incomplete | Incomplete - Applies to: CoaXPress. | |
OverflowEventSelect_IncompleteLost | IncompleteLost - Applies to: CoaXPress. | |
OverflowEventSelect_IncompleteOK | IncompleteOK - Applies to: CoaXPress. | |
OverflowEventSelect_Lost | Lost - Applies to: CoaXPress. | |
OverflowEventSelect_LostOK | LostOK - Applies to: CoaXPress. | |
OverflowEventSelect_OK | OK - Applies to: CoaXPress. |
Valid values for OverflowEventSelect.
enum PixelFormatEnums#
Enumerator | Value | Description |
---|---|---|
PixelFormat_BayerBG10p | The pixel format is set to BayerBG10p - Applies to: CoaXPress. | |
PixelFormat_BayerBG12p | The pixel format is set to BayerBG12p - Applies to: CoaXPress. | |
PixelFormat_BayerBG14p | The pixel format is set to BayerBG14p - Applies to: CoaXPress. | |
PixelFormat_BayerBG8 | The pixel format is set to BayerBG8 - Applies to: CoaXPress. | |
PixelFormat_BayerGB10p | The pixel format is set to BayerGB10p - Applies to: CoaXPress. | |
PixelFormat_BayerGB12p | The pixel format is set to BayerGB12p - Applies to: CoaXPress. | |
PixelFormat_BayerGB14p | The pixel format is set to BayerGB14p - Applies to: CoaXPress. | |
PixelFormat_BayerGB8 | The pixel format is set to BayerGB8 - Applies to: CoaXPress. | |
PixelFormat_BayerGR10p | The pixel format is set to BayerGR10p - Applies to: CoaXPress. | |
PixelFormat_BayerGR12p | The pixel format is set to BayerGR12p - Applies to: CoaXPress. | |
PixelFormat_BayerGR14p | The pixel format is set to BayerGR14p - Applies to: CoaXPress. | |
PixelFormat_BayerGR8 | The pixel format is set to BayerGR8 - Applies to: CoaXPress. | |
PixelFormat_BayerRG10p | The pixel format is set to BayerRG10p - Applies to: CoaXPress. | |
PixelFormat_BayerRG12p | The pixel format is set to BayerRG12p - Applies to: CoaXPress. | |
PixelFormat_BayerRG14p | The pixel format is set to BayerRG14p - Applies to: CoaXPress. | |
PixelFormat_BayerRG8 | The pixel format is set to BayerRG8 - Applies to: CoaXPress. | |
PixelFormat_Mono10 | The pixel format is set to Mono10 - Applies to: CoaXPress. | |
PixelFormat_Mono10p | The pixel output format is set to Mono10p - Applies to: CoaXPress. | |
PixelFormat_Mono12 | The pixel format is set to Mono12 - Applies to: CoaXPress. | |
PixelFormat_Mono12p | The pixel output format is set to Mono12p - Applies to: CoaXPress. | |
PixelFormat_Mono14p | The pixel output format is set to Mono14p - Applies to: CoaXPress. | |
PixelFormat_Mono16 | The pixel format is set to Mono16 - Applies to: CoaXPress. | |
PixelFormat_Mono8 | The pixel format is set to Mono8 - Applies to: CoaXPress. | |
PixelFormat_RGB10p | The pixel format is set to RGB10p - Applies to: CoaXPress. | |
PixelFormat_RGB12p | The pixel format is set to RGB12p - Applies to: CoaXPress. | |
PixelFormat_RGB14p | The pixel format is set to RGB14p - Applies to: CoaXPress. | |
PixelFormat_RGB16 | The pixel format is set to RGB16 - Applies to: CoaXPress. | |
PixelFormat_RGB8 | The pixel format is set to RGB8 - Applies to: CoaXPress. | |
PixelFormat_YCbCr422_8 | The pixel format is set to YCbCr422_8 - Applies to: CoaXPress. |
Valid values for PixelFormat.
enum ProcessingInvertEnums#
Enumerator | Value | Description |
---|---|---|
ProcessingInvert_Off | The trigger queue mode is disabled - Applies to: CoaXPress. | |
ProcessingInvert_On | The trigger queue mode is enabled - Applies to: CoaXPress. |
Valid values for ProcessingInvert.
enum SoftwareTriggerIsBusyEnums#
Enumerator | Value | Description |
---|---|---|
SoftwareTriggerIsBusy_Busy | The software trigger is busy - Applies to: CoaXPress. | |
SoftwareTriggerIsBusy_NotBusy | The software trigger is not busy - Applies to: CoaXPress. |
Valid values for SoftwareTriggerIsBusy.
enum SystemmonitorByteAlignment8b10bLockedEnums#
Enumerator | Value | Description |
---|---|---|
SystemmonitorByteAlignment8b10bLocked_No | No - Applies to: CoaXPress. | |
SystemmonitorByteAlignment8b10bLocked_Yes | Yes - Applies to: CoaXPress. |
Valid values for SystemmonitorByteAlignment8b10bLocked.
enum SystemmonitorExternalPowerEnums#
Enumerator | Value | Description |
---|---|---|
SystemmonitorExternalPower_NoPower | No power - Applies to: CoaXPress. | |
SystemmonitorExternalPower_PowerGood | Power is ok - Applies to: CoaXPress. |
Valid values for SystemmonitorExternalPower.
enum SystemmonitorPowerOverCxpStateEnums#
Enumerator | Value | Description |
---|---|---|
SystemmonitorPowerOverCxpState_PoCXPADCChipError | ADC Chip Error - Applies to: CoaXPress. | |
SystemmonitorPowerOverCxpState_PoCXPBooting | Booting, not initalized - Applies to: CoaXPress. | |
SystemmonitorPowerOverCxpState_PoCXPDisabled | No Power over CXP - Applies to: CoaXPress. | |
SystemmonitorPowerOverCxpState_PoCXPLowVolt | Low voltage - Applies to: CoaXPress. | |
SystemmonitorPowerOverCxpState_PoCXPMaxCurrent | Maximum current - Applies to: CoaXPress. | |
SystemmonitorPowerOverCxpState_PoCXPMinCurrent | Minimum current - Applies to: CoaXPress. | |
SystemmonitorPowerOverCxpState_PoCXPNotConnected | No cable connected - Applies to: CoaXPress. | |
SystemmonitorPowerOverCxpState_PoCXPOK | Power over CXP OK - Applies to: CoaXPress. | |
SystemmonitorPowerOverCxpState_PoCXPOverVolt | Over voltage - Applies to: CoaXPress. |
Valid values for SystemmonitorPowerOverCxpState.
enum TriggerCameraOutSelectEnums#
Enumerator | Value | Description |
---|---|---|
TriggerCameraOutSelect_BypassFrontGPI0 | The output source is set to BypassFrontGPI0 - Applies to: CoaXPress. | |
TriggerCameraOutSelect_BypassFrontGPI1 | The output source is set to BypassFrontGPI1 - Applies to: CoaXPress. | |
TriggerCameraOutSelect_BypassFrontGPI2 | The output source is set to BypassFrontGPI2 - Applies to: CoaXPress. | |
TriggerCameraOutSelect_BypassFrontGPI3 | The output source is set to BypassFrontGPI3 - Applies to: CoaXPress. | |
TriggerCameraOutSelect_BypassGPI0 | Bypass the GPI 0 signal directly to the output - Applies to: CoaXPress. | |
TriggerCameraOutSelect_BypassGPI1 | Bypass the GPI 1 signal directly to the output - Applies to: CoaXPress. | |
TriggerCameraOutSelect_BypassGPI2 | Bypass the GPI 2 signal directly to the output - Applies to: CoaXPress. | |
TriggerCameraOutSelect_BypassGPI3 | Bypass the GPI 3 signal directly to the output - Applies to: CoaXPress. | |
TriggerCameraOutSelect_BypassGPI4 | Bypass the GPI 4 signal directly to the output - Applies to: CoaXPress. | |
TriggerCameraOutSelect_BypassGPI5 | Bypass the GPI 5 signal directly to the output - Applies to: CoaXPress. | |
TriggerCameraOutSelect_BypassGPI6 | Bypass the GPI 6 signal directly to the output - Applies to: CoaXPress. | |
TriggerCameraOutSelect_BypassGPI7 | Bypass the GPI 7 signal directly to the output - Applies to: CoaXPress. | |
TriggerCameraOutSelect_CamAPulseGenerator0 | The output source is set to CamAPulseGenerator0 - Applies to: CoaXPress. | |
TriggerCameraOutSelect_CamAPulseGenerator1 | The output source is set to CamAPulseGenerator1 - Applies to: CoaXPress. | |
TriggerCameraOutSelect_CamAPulseGenerator2 | The output source is set to CamAPulseGenerator2 - Applies to: CoaXPress. | |
TriggerCameraOutSelect_CamAPulseGenerator3 | The output source is set to CamAPulseGenerator3 - Applies to: CoaXPress. | |
TriggerCameraOutSelect_CamBPulseGenerator0 | The output source is set to Cam B Pulse Generator 0 - Applies to: CoaXPress. | |
TriggerCameraOutSelect_CamBPulseGenerator1 | The output source is set to Cam B Pulse Generator 1 - Applies to: CoaXPress. | |
TriggerCameraOutSelect_CamBPulseGenerator2 | The output source is set to Cam B Pulse Generator 2 - Applies to: CoaXPress. | |
TriggerCameraOutSelect_CamBPulseGenerator3 | The output source is set to Cam B Pulse Generator 3 - Applies to: CoaXPress. | |
TriggerCameraOutSelect_CamCPulseGenerator0 | The output source is set to Cam C Pulse Generator 0 - Applies to: CoaXPress. | |
TriggerCameraOutSelect_CamCPulseGenerator1 | The output source is set to Cam C Pulse Generator 1 - Applies to: CoaXPress. | |
TriggerCameraOutSelect_CamCPulseGenerator2 | The output source is set to Cam C Pulse Generator 2 - Applies to: CoaXPress. | |
TriggerCameraOutSelect_CamCPulseGenerator3 | The output source is set to Cam C Pulse Generator 3 - Applies to: CoaXPress. | |
TriggerCameraOutSelect_CamDPulseGenerator0 | The output source is set to Cam D Pulse Generator 0 - Applies to: CoaXPress. | |
TriggerCameraOutSelect_CamDPulseGenerator1 | The output source is set to Cam D Pulse Generator 1 - Applies to: CoaXPress. | |
TriggerCameraOutSelect_CamDPulseGenerator2 | The output source is set to Cam D Pulse Generator 2 - Applies to: CoaXPress. | |
TriggerCameraOutSelect_CamDPulseGenerator3 | The output source is set to Cam D Pulse Generator 3 - Applies to: CoaXPress. | |
TriggerCameraOutSelect_GND | The output source is set to GND - Applies to: CoaXPress. | |
TriggerCameraOutSelect_NotBypassFronGPI0 | The output source is set to NotBypassFrontGPI0 - Applies to: CoaXPress. | |
TriggerCameraOutSelect_NotBypassFronGPI1 | The output source is set to NotBypassFrontGPI1 - Applies to: CoaXPress. | |
TriggerCameraOutSelect_NotBypassFronGPI2 | The output source is set to NotBypassFrontGPI2 - Applies to: CoaXPress. | |
TriggerCameraOutSelect_NotBypassFronGPI3 | The output source is set to NotBypassFrontGPI3 - Applies to: CoaXPress. | |
TriggerCameraOutSelect_NotBypassFrontGPI0 | The output source is set to Not Bypass Front-GPI 0 - Applies to: CoaXPress. | |
TriggerCameraOutSelect_NotBypassFrontGPI1 | The output source is set to Not Bypass Front-GPI 1 - Applies to: CoaXPress. | |
TriggerCameraOutSelect_NotBypassFrontGPI2 | The output source is set to Not Bypass Front-GPI 2 - Applies to: CoaXPress. | |
TriggerCameraOutSelect_NotBypassFrontGPI3 | The output source is set to Not Bypass Front-GPI 3 - Applies to: CoaXPress. | |
TriggerCameraOutSelect_NotBypassGPI0 | Bypass the inverted GPI 0 signal directly to the output - Applies to: CoaXPress. | |
TriggerCameraOutSelect_NotBypassGPI1 | Bypass the inverted GPI 1 signal directly to the output - Applies to: CoaXPress. | |
TriggerCameraOutSelect_NotBypassGPI2 | Bypass the inverted GPI 2 signal directly to the output - Applies to: CoaXPress. | |
TriggerCameraOutSelect_NotBypassGPI3 | Bypass the inverted GPI 3 signal directly to the output - Applies to: CoaXPress. | |
TriggerCameraOutSelect_NotBypassGPI4 | Bypass the inverted GPI 4 signal directly to the output - Applies to: CoaXPress. | |
TriggerCameraOutSelect_NotBypassGPI5 | Bypass the inverted GPI 5 signal directly to the output - Applies to: CoaXPress. | |
TriggerCameraOutSelect_NotBypassGPI6 | Bypass the inverted GPI 6 signal directly to the output - Applies to: CoaXPress. | |
TriggerCameraOutSelect_NotBypassGPI7 | Bypass the inverted GPI 7 signal directly to the output - Applies to: CoaXPress. | |
TriggerCameraOutSelect_NotCamAPulseGenerator0 | The output source is set to NotCamAPulseGenerator0 - Applies to: CoaXPress. | |
TriggerCameraOutSelect_NotCamAPulseGenerator1 | The output source is set to NotCamAPulseGenerator1 - Applies to: CoaXPress. | |
TriggerCameraOutSelect_NotCamAPulseGenerator2 | The output source is set to NotCamAPulseGenerator2 - Applies to: CoaXPress. | |
TriggerCameraOutSelect_NotCamAPulseGenerator3 | The output source is set to NotCamAPulseGenerator3 - Applies to: CoaXPress. | |
TriggerCameraOutSelect_NotCamBPulseGenerator0 | The output source is set to Not Cam B Pulse Generator 0 - Applies to: CoaXPress. | |
TriggerCameraOutSelect_NotCamBPulseGenerator1 | The output source is set to Not Cam B Pulse Generator 1 - Applies to: CoaXPress. | |
TriggerCameraOutSelect_NotCamBPulseGenerator2 | The output source is set to Not Cam B Pulse Generator 2 - Applies to: CoaXPress. | |
TriggerCameraOutSelect_NotCamBPulseGenerator3 | The output source is set to Not Cam B Pulse Generator 3 - Applies to: CoaXPress. | |
TriggerCameraOutSelect_NotCamCPulseGenerator0 | The output source is set to Not Cam C Pulse Generator 0 - Applies to: CoaXPress. | |
TriggerCameraOutSelect_NotCamCPulseGenerator1 | The output source is set to Not Cam C Pulse Generator 1 - Applies to: CoaXPress. | |
TriggerCameraOutSelect_NotCamCPulseGenerator2 | The output source is set to Not Cam C Pulse Generator 2 - Applies to: CoaXPress. | |
TriggerCameraOutSelect_NotCamCPulseGenerator3 | The output source is set to Not Cam C Pulse Generator 3 - Applies to: CoaXPress. | |
TriggerCameraOutSelect_NotCamDPulseGenerator0 | The output source is set to Not Cam D Pulse Generator 0 - Applies to: CoaXPress. | |
TriggerCameraOutSelect_NotCamDPulseGenerator1 | The output source is set to Not Cam D Pulse Generator 1 - Applies to: CoaXPress. | |
TriggerCameraOutSelect_NotCamDPulseGenerator2 | The output source is set to Not Cam D Pulse Generator 2 - Applies to: CoaXPress. | |
TriggerCameraOutSelect_NotCamDPulseGenerator3 | The output source is set to Not Cam D Pulse Generator 3 - Applies to: CoaXPress. | |
TriggerCameraOutSelect_NotPulseGenerator0 | The output source is set to NotPulseGenerator0 - Applies to: CoaXPress. | |
TriggerCameraOutSelect_NotPulseGenerator1 | The output source is set to NotPulseGenerator1 - Applies to: CoaXPress. | |
TriggerCameraOutSelect_NotPulseGenerator2 | The output source is set to NotPulseGenerator2 - Applies to: CoaXPress. | |
TriggerCameraOutSelect_NotPulseGenerator3 | The output source is set to NotPulseGenerator3 - Applies to: CoaXPress. | |
TriggerCameraOutSelect_PulseGenerator0 | The output source is set to PulseGenerator0 - Applies to: CoaXPress. | |
TriggerCameraOutSelect_PulseGenerator1 | The output source is set to PulseGenerator1 - Applies to: CoaXPress. | |
TriggerCameraOutSelect_PulseGenerator2 | The output source is set to PulseGenerator2 - Applies to: CoaXPress. | |
TriggerCameraOutSelect_PulseGenerator3 | The output source is set to PulseGenerator3 - Applies to: CoaXPress. | |
TriggerCameraOutSelect_VCC | The output source is set to VCC - Applies to: CoaXPress. |
Valid values for TriggerCameraOutSelect.
enum TriggerExceededPeriodLimitsEnums#
Enumerator | Value | Description |
---|---|---|
TriggerExceededPeriodLimits_No | The input signal frequency hasn't exceeded the maximum frequency defined by the Trigger Output Frequency parameter - Applies to: CoaXPress. | |
TriggerExceededPeriodLimits_Yes | The input signal frequency has exceeded the maximum frequency defined by the Trigger Output Frequency parameter - Applies to: CoaXPress. |
Valid values for TriggerExceededPeriodLimits.
enum TriggerInPolarityEnums#
Enumerator | Value | Description |
---|---|---|
TriggerInPolarity_HighActive | The polarity is set to HighActive - Applies to: CoaXPress. | |
TriggerInPolarity_LowActive | The polarity is set to LowActive - Applies to: CoaXPress. |
Valid values for TriggerInPolarity.
enum TriggerInSourceEnums#
Enumerator | Value | Description |
---|---|---|
TriggerInSource_GPITriggerSource0 | GPI Trigger Source 0 - Applies to: CoaXPress. | |
TriggerInSource_GPITriggerSource1 | GPI Trigger Source 1 - Applies to: CoaXPress. | |
TriggerInSource_GPITriggerSource2 | GPI Trigger Source 2 - Applies to: CoaXPress. | |
TriggerInSource_GPITriggerSource3 | GPI Trigger Source 3 - Applies to: CoaXPress. | |
TriggerInSource_GPITriggerSource4 | GPI Trigger Source 4 - Applies to: CoaXPress. | |
TriggerInSource_GPITriggerSource5 | GPI Trigger Source 5 - Applies to: CoaXPress. | |
TriggerInSource_GPITriggerSource6 | GPI Trigger Source 6 - Applies to: CoaXPress. | |
TriggerInSource_GPITriggerSource7 | GPI Trigger Source 7 - Applies to: CoaXPress. | |
TriggerInSource_TriggerInSourceFrontGPI0 | The trigger input source is set to TriggerInSourceFrontGPI0 - Applies to: CoaXPress. | |
TriggerInSource_TriggerInSourceFrontGPI1 | The trigger input source is set to TriggerInSourceFrontGPI1 - Applies to: CoaXPress. | |
TriggerInSource_TriggerInSourceFrontGPI2 | The trigger input source is set to TriggerInSourceFrontGPI2 - Applies to: CoaXPress. | |
TriggerInSource_TriggerInSourceFrontGPI3 | The trigger input source is set to TriggerInSourceFrontGPI3 - Applies to: CoaXPress. |
Valid values for TriggerInSource.
enum TriggerInStatisticsPolarityEnums#
Enumerator | Value | Description |
---|---|---|
TriggerInStatisticsPolarity_HighActive | The trigger polarity of the input specified by the Statistics Source parameter is set to High Active - Applies to: CoaXPress. | |
TriggerInStatisticsPolarity_LowActive | The trigger polarity of the input specified by the Statistics Source parameter is set to Low Active - Applies to: CoaXPress. |
Valid values for TriggerInStatisticsPolarity.
enum TriggerInStatisticsSourceEnums#
Enumerator | Value | Description |
---|---|---|
TriggerInStatisticsSource_GPITriggerSource0 | GPI Trigger Source 0 - Applies to: CoaXPress. | |
TriggerInStatisticsSource_GPITriggerSource1 | GPI Trigger Source 1 - Applies to: CoaXPress. | |
TriggerInStatisticsSource_GPITriggerSource2 | GPI Trigger Source 2 - Applies to: CoaXPress. | |
TriggerInStatisticsSource_GPITriggerSource3 | GPI Trigger Source 3 - Applies to: CoaXPress. | |
TriggerInStatisticsSource_GPITriggerSource4 | GPI Trigger Source 4 - Applies to: CoaXPress. | |
TriggerInStatisticsSource_GPITriggerSource5 | GPI Trigger Source 5 - Applies to: CoaXPress. | |
TriggerInStatisticsSource_GPITriggerSource6 | GPI Trigger Source 6 - Applies to: CoaXPress. | |
TriggerInStatisticsSource_GPITriggerSource7 | GPI Trigger Source 7 - Applies to: CoaXPress. | |
TriggerInStatisticsSource_TriggerInSourceFrontGPI0 | The input source of the trigger statistics is set to Front GPI Trigger Source 0 - Applies to: CoaXPress. | |
TriggerInStatisticsSource_TriggerInSourceFrontGPI1 | The input source of the trigger statistics is set to Front GPI Trigger Source 1 - Applies to: CoaXPress. | |
TriggerInStatisticsSource_TriggerInSourceFrontGPI2 | The input source of the trigger statistics is set to Front GPI Trigger Source 2 - Applies to: CoaXPress. | |
TriggerInStatisticsSource_TriggerInSourceFrontGPI3 | The input source of the trigger statistics is set to Front GPI Trigger Source 3 - Applies to: CoaXPress. |
Valid values for TriggerInStatisticsSource.
enum TriggerOutSelectFrontGPO0Enums#
Enumerator | Value | Description |
---|---|---|
TriggerOutSelectFrontGPO0_BypassFrontGPI0 | The output source is set to BypassFrontGPI0 - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO0_BypassFrontGPI1 | The output source is set to BypassFrontGPI1 - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO0_BypassFrontGPI2 | The output source is set to BypassFrontGPI2 - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO0_BypassFrontGPI3 | The output source is set to BypassFrontGPI3 - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO0_BypassGPI0 | Bypass the GPI 0 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO0_BypassGPI1 | Bypass the GPI 1 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO0_BypassGPI2 | Bypass the GPI 2 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO0_BypassGPI3 | Bypass the GPI 3 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO0_BypassGPI4 | Bypass the GPI 4 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO0_BypassGPI5 | Bypass the GPI 5 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO0_BypassGPI6 | Bypass the GPI 6 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO0_BypassGPI7 | Bypass the GPI 7 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO0_CamAPulseGenerator0 | The output source is set to CamAPulseGenerator0 - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO0_CamAPulseGenerator1 | The output source is set to CamAPulseGenerator1 - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO0_CamAPulseGenerator2 | The output source is set to CamAPulseGenerator2 - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO0_CamAPulseGenerator3 | The output source is set to CamAPulseGenerator3 - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO0_CamBPulseGenerator0 | The output source is set to Cam B Pulse Generator 0 - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO0_CamBPulseGenerator1 | The output source is set to Cam B Pulse Generator 1 - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO0_CamBPulseGenerator2 | The output source is set to Cam B Pulse Generator 2 - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO0_CamBPulseGenerator3 | The output source is set to Cam B Pulse Generator 3 - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO0_CamCPulseGenerator0 | The output source is set to Cam C Pulse Generator 0 - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO0_CamCPulseGenerator1 | The output source is set to Cam C Pulse Generator 1 - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO0_CamCPulseGenerator2 | The output source is set to Cam C Pulse Generator 2 - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO0_CamCPulseGenerator3 | The output source is set to Cam C Pulse Generator 3 - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO0_CamDPulseGenerator0 | The output source is set to Cam D Pulse Generator 0 - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO0_CamDPulseGenerator1 | The output source is set to Cam D Pulse Generator 1 - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO0_CamDPulseGenerator2 | The output source is set to Cam D Pulse Generator 2 - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO0_CamDPulseGenerator3 | The output source is set to Cam D Pulse Generator 3 - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO0_GND | The output source is set to GND - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO0_NotBypassFronGPI0 | The output source is set to NotBypassFrontGPI0 - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO0_NotBypassFronGPI1 | The output source is set to NotBypassFrontGPI1 - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO0_NotBypassFronGPI2 | The output source is set to NotBypassFrontGPI2 - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO0_NotBypassFronGPI3 | The output source is set to NotBypassFrontGPI3 - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO0_NotBypassFrontGPI0 | The output source is set to Not Bypass Front-GPI 0 - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO0_NotBypassFrontGPI1 | The output source is set to Not Bypass Front-GPI 1 - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO0_NotBypassFrontGPI2 | The output source is set to Not Bypass Front-GPI 2 - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO0_NotBypassFrontGPI3 | The output source is set to Not Bypass Front-GPI 3 - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO0_NotBypassGPI0 | Bypass the inverted GPI 0 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO0_NotBypassGPI1 | Bypass the inverted GPI 1 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO0_NotBypassGPI2 | Bypass the inverted GPI 2 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO0_NotBypassGPI3 | Bypass the inverted GPI 3 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO0_NotBypassGPI4 | Bypass the inverted GPI 4 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO0_NotBypassGPI5 | Bypass the inverted GPI 5 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO0_NotBypassGPI6 | Bypass the inverted GPI 6 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO0_NotBypassGPI7 | Bypass the inverted GPI 7 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO0_NotCamAPulseGenerator0 | The output source is set to NotCamAPulseGenerator0 - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO0_NotCamAPulseGenerator1 | The output source is set to NotCamAPulseGenerator1 - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO0_NotCamAPulseGenerator2 | The output source is set to NotCamAPulseGenerator2 - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO0_NotCamAPulseGenerator3 | The output source is set to NotCamAPulseGenerator3 - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO0_NotCamBPulseGenerator0 | The output source is set to Not Cam B Pulse Generator 0 - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO0_NotCamBPulseGenerator1 | The output source is set to Not Cam B Pulse Generator 1 - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO0_NotCamBPulseGenerator2 | The output source is set to Not Cam B Pulse Generator 2 - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO0_NotCamBPulseGenerator3 | The output source is set to Not Cam B Pulse Generator 3 - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO0_NotCamCPulseGenerator0 | The output source is set to Not Cam C Pulse Generator 0 - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO0_NotCamCPulseGenerator1 | The output source is set to Not Cam C Pulse Generator 1 - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO0_NotCamCPulseGenerator2 | The output source is set to Not Cam C Pulse Generator 2 - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO0_NotCamCPulseGenerator3 | The output source is set to Not Cam C Pulse Generator 3 - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO0_NotCamDPulseGenerator0 | The output source is set to Not Cam D Pulse Generator 0 - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO0_NotCamDPulseGenerator1 | The output source is set to Not Cam D Pulse Generator 1 - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO0_NotCamDPulseGenerator2 | The output source is set to Not Cam D Pulse Generator 2 - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO0_NotCamDPulseGenerator3 | The output source is set to Not Cam D Pulse Generator 3 - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO0_NotPulseGenerator0 | The output source is set to NotPulseGenerator0 - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO0_NotPulseGenerator1 | The output source is set to NotPulseGenerator1 - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO0_NotPulseGenerator2 | The output source is set to NotPulseGenerator2 - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO0_NotPulseGenerator3 | The output source is set to NotPulseGenerator3 - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO0_PulseGenerator0 | The output source is set to PulseGenerator0 - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO0_PulseGenerator1 | The output source is set to PulseGenerator1 - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO0_PulseGenerator2 | The output source is set to PulseGenerator2 - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO0_PulseGenerator3 | The output source is set to PulseGenerator3 - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO0_VCC | The output source is set to VCC - Applies to: CoaXPress. |
Valid values for TriggerOutSelectFrontGPO0.
enum TriggerOutSelectFrontGPO1Enums#
Enumerator | Value | Description |
---|---|---|
TriggerOutSelectFrontGPO1_BypassFrontGPI0 | The output source is set to BypassFrontGPI0 - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO1_BypassFrontGPI1 | The output source is set to BypassFrontGPI1 - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO1_BypassFrontGPI2 | The output source is set to BypassFrontGPI2 - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO1_BypassFrontGPI3 | The output source is set to BypassFrontGPI3 - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO1_BypassGPI0 | Bypass the GPI 0 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO1_BypassGPI1 | Bypass the GPI 1 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO1_BypassGPI2 | Bypass the GPI 2 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO1_BypassGPI3 | Bypass the GPI 3 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO1_BypassGPI4 | Bypass the GPI 4 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO1_BypassGPI5 | Bypass the GPI 5 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO1_BypassGPI6 | Bypass the GPI 6 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO1_BypassGPI7 | Bypass the GPI 7 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO1_CamAPulseGenerator0 | The output source is set to CamAPulseGenerator0 - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO1_CamAPulseGenerator1 | The output source is set to CamAPulseGenerator1 - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO1_CamAPulseGenerator2 | The output source is set to CamAPulseGenerator2 - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO1_CamAPulseGenerator3 | The output source is set to CamAPulseGenerator3 - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO1_CamBPulseGenerator0 | The output source is set to Cam B Pulse Generator 0 - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO1_CamBPulseGenerator1 | The output source is set to Cam B Pulse Generator 1 - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO1_CamBPulseGenerator2 | The output source is set to Cam B Pulse Generator 2 - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO1_CamBPulseGenerator3 | The output source is set to Cam B Pulse Generator 3 - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO1_CamCPulseGenerator0 | The output source is set to Cam C Pulse Generator 0 - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO1_CamCPulseGenerator1 | The output source is set to Cam C Pulse Generator 1 - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO1_CamCPulseGenerator2 | The output source is set to Cam C Pulse Generator 2 - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO1_CamCPulseGenerator3 | The output source is set to Cam C Pulse Generator 3 - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO1_CamDPulseGenerator0 | The output source is set to Cam D Pulse Generator 0 - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO1_CamDPulseGenerator1 | The output source is set to Cam D Pulse Generator 1 - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO1_CamDPulseGenerator2 | The output source is set to Cam D Pulse Generator 2 - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO1_CamDPulseGenerator3 | The output source is set to Cam D Pulse Generator 3 - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO1_GND | The output source is set to GND - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO1_NotBypassFronGPI0 | The output source is set to NotBypassFrontGPI0 - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO1_NotBypassFronGPI1 | The output source is set to NotBypassFrontGPI1 - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO1_NotBypassFronGPI2 | The output source is set to NotBypassFrontGPI2 - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO1_NotBypassFronGPI3 | The output source is set to NotBypassFrontGPI3 - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO1_NotBypassFrontGPI0 | The output source is set to Not Bypass Front-GPI 0 - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO1_NotBypassFrontGPI1 | The output source is set to Not Bypass Front-GPI 1 - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO1_NotBypassFrontGPI2 | The output source is set to Not Bypass Front-GPI 2 - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO1_NotBypassFrontGPI3 | The output source is set to Not Bypass Front-GPI 3 - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO1_NotBypassGPI0 | Bypass the inverted GPI 0 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO1_NotBypassGPI1 | Bypass the inverted GPI 1 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO1_NotBypassGPI2 | Bypass the inverted GPI 2 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO1_NotBypassGPI3 | Bypass the inverted GPI 3 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO1_NotBypassGPI4 | Bypass the inverted GPI 4 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO1_NotBypassGPI5 | Bypass the inverted GPI 5 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO1_NotBypassGPI6 | Bypass the inverted GPI 6 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO1_NotBypassGPI7 | Bypass the inverted GPI 7 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO1_NotCamAPulseGenerator0 | The output source is set to NotCamAPulseGenerator0 - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO1_NotCamAPulseGenerator1 | The output source is set to NotCamAPulseGenerator1 - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO1_NotCamAPulseGenerator2 | The output source is set to NotCamAPulseGenerator2 - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO1_NotCamAPulseGenerator3 | The output source is set to NotCamAPulseGenerator3 - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO1_NotCamBPulseGenerator0 | The output source is set to Not Cam B Pulse Generator 0 - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO1_NotCamBPulseGenerator1 | The output source is set to Not Cam B Pulse Generator 1 - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO1_NotCamBPulseGenerator2 | The output source is set to Not Cam B Pulse Generator 2 - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO1_NotCamBPulseGenerator3 | The output source is set to Not Cam B Pulse Generator 3 - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO1_NotCamCPulseGenerator0 | The output source is set to Not Cam C Pulse Generator 0 - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO1_NotCamCPulseGenerator1 | The output source is set to Not Cam C Pulse Generator 1 - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO1_NotCamCPulseGenerator2 | The output source is set to Not Cam C Pulse Generator 2 - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO1_NotCamCPulseGenerator3 | The output source is set to Not Cam C Pulse Generator 3 - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO1_NotCamDPulseGenerator0 | The output source is set to Not Cam D Pulse Generator 0 - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO1_NotCamDPulseGenerator1 | The output source is set to Not Cam D Pulse Generator 1 - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO1_NotCamDPulseGenerator2 | The output source is set to Not Cam D Pulse Generator 2 - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO1_NotCamDPulseGenerator3 | The output source is set to Not Cam D Pulse Generator 3 - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO1_NotPulseGenerator0 | The output source is set to NotPulseGenerator0 - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO1_NotPulseGenerator1 | The output source is set to NotPulseGenerator1 - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO1_NotPulseGenerator2 | The output source is set to NotPulseGenerator2 - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO1_NotPulseGenerator3 | The output source is set to NotPulseGenerator3 - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO1_PulseGenerator0 | The output source is set to PulseGenerator0 - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO1_PulseGenerator1 | The output source is set to PulseGenerator1 - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO1_PulseGenerator2 | The output source is set to PulseGenerator2 - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO1_PulseGenerator3 | The output source is set to PulseGenerator3 - Applies to: CoaXPress. | |
TriggerOutSelectFrontGPO1_VCC | The output source is set to VCC - Applies to: CoaXPress. |
Valid values for TriggerOutSelectFrontGPO1.
enum TriggerOutSelectGPO0Enums#
Enumerator | Value | Description |
---|---|---|
TriggerOutSelectGPO0_BypassFrontGPI0 | Bypass the Front GPI 0 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO0_BypassFrontGPI1 | Bypass the Front GPI 1 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO0_BypassFrontGPI2 | Bypass the Front GPI 2 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO0_BypassFrontGPI3 | Bypass the Front GPI 3 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO0_BypassGPI0 | Bypass the GPI 0 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO0_BypassGPI1 | Bypass the GPI 1 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO0_BypassGPI2 | Bypass the GPI 2 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO0_BypassGPI3 | Bypass the GPI 3 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO0_BypassGPI4 | Bypass the GPI 4 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO0_BypassGPI5 | Bypass the GPI 5 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO0_BypassGPI6 | Bypass the GPI 6 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO0_BypassGPI7 | Bypass the GPI 7 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO0_CamAPulseGenerator0 | Camera port A Pulse Generator 0 - Applies to: CoaXPress. | |
TriggerOutSelectGPO0_CamAPulseGenerator1 | Camera port A Pulse Generator 1 - Applies to: CoaXPress. | |
TriggerOutSelectGPO0_CamAPulseGenerator2 | Camera port A Pulse Generator 2 - Applies to: CoaXPress. | |
TriggerOutSelectGPO0_CamAPulseGenerator3 | Camera port A Pulse Generator 3 - Applies to: CoaXPress. | |
TriggerOutSelectGPO0_CamBPulseGenerator0 | The output source is set to Cam B Pulse Generator 0 - Applies to: CoaXPress. | |
TriggerOutSelectGPO0_CamBPulseGenerator1 | The output source is set to Cam B Pulse Generator 1 - Applies to: CoaXPress. | |
TriggerOutSelectGPO0_CamBPulseGenerator2 | The output source is set to Cam B Pulse Generator 2 - Applies to: CoaXPress. | |
TriggerOutSelectGPO0_CamBPulseGenerator3 | The output source is set to Cam B Pulse Generator 3 - Applies to: CoaXPress. | |
TriggerOutSelectGPO0_CamCPulseGenerator0 | The output source is set to Cam C Pulse Generator 0 - Applies to: CoaXPress. | |
TriggerOutSelectGPO0_CamCPulseGenerator1 | The output source is set to Cam C Pulse Generator 1 - Applies to: CoaXPress. | |
TriggerOutSelectGPO0_CamCPulseGenerator2 | The output source is set to Cam C Pulse Generator 2 - Applies to: CoaXPress. | |
TriggerOutSelectGPO0_CamCPulseGenerator3 | The output source is set to Cam C Pulse Generator 3 - Applies to: CoaXPress. | |
TriggerOutSelectGPO0_CamDPulseGenerator0 | The output source is set to Cam D Pulse Generator 0 - Applies to: CoaXPress. | |
TriggerOutSelectGPO0_CamDPulseGenerator1 | The output source is set to Cam D Pulse Generator 1 - Applies to: CoaXPress. | |
TriggerOutSelectGPO0_CamDPulseGenerator2 | The output source is set to Cam D Pulse Generator 2 - Applies to: CoaXPress. | |
TriggerOutSelectGPO0_CamDPulseGenerator3 | The output source is set to Cam D Pulse Generator 3 - Applies to: CoaXPress. | |
TriggerOutSelectGPO0_GND | A static zero - Applies to: CoaXPress. | |
TriggerOutSelectGPO0_NotBypassFrontGPI0 | The output source is set to Not Bypass Front-GPI 0 - Applies to: CoaXPress. | |
TriggerOutSelectGPO0_NotBypassFrontGPI1 | The output source is set to Not Bypass Front-GPI 1 - Applies to: CoaXPress. | |
TriggerOutSelectGPO0_NotBypassFrontGPI2 | The output source is set to Not Bypass Front-GPI 2 - Applies to: CoaXPress. | |
TriggerOutSelectGPO0_NotBypassFrontGPI3 | The output source is set to Not Bypass Front-GPI 3 - Applies to: CoaXPress. | |
TriggerOutSelectGPO0_NotBypassGPI0 | Bypass the inverted GPI 0 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO0_NotBypassGPI1 | Bypass the inverted GPI 1 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO0_NotBypassGPI2 | Bypass the inverted GPI 2 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO0_NotBypassGPI3 | Bypass the inverted GPI 3 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO0_NotBypassGPI4 | Bypass the inverted GPI 4 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO0_NotBypassGPI5 | Bypass the inverted GPI 5 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO0_NotBypassGPI6 | Bypass the inverted GPI 6 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO0_NotBypassGPI7 | Bypass the inverted GPI 7 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO0_NotCamAPulseGenerator0 | Inverted signal of camera port A Pulse Generator 0 - Applies to: CoaXPress. | |
TriggerOutSelectGPO0_NotCamAPulseGenerator1 | Inverted signal of camera port A Pulse Generator 1 - Applies to: CoaXPress. | |
TriggerOutSelectGPO0_NotCamAPulseGenerator2 | Inverted signal of camera port A Pulse Generator 2 - Applies to: CoaXPress. | |
TriggerOutSelectGPO0_NotCamAPulseGenerator3 | Inverted signal of camera port A Pulse Generator 3 - Applies to: CoaXPress. | |
TriggerOutSelectGPO0_NotCamBPulseGenerator0 | The output source is set to Not Cam B Pulse Generator 0 - Applies to: CoaXPress. | |
TriggerOutSelectGPO0_NotCamBPulseGenerator1 | The output source is set to Not Cam B Pulse Generator 1 - Applies to: CoaXPress. | |
TriggerOutSelectGPO0_NotCamBPulseGenerator2 | The output source is set to Not Cam B Pulse Generator 2 - Applies to: CoaXPress. | |
TriggerOutSelectGPO0_NotCamBPulseGenerator3 | The output source is set to Not Cam B Pulse Generator 3 - Applies to: CoaXPress. | |
TriggerOutSelectGPO0_NotCamCPulseGenerator0 | The output source is set to Not Cam C Pulse Generator 0 - Applies to: CoaXPress. | |
TriggerOutSelectGPO0_NotCamCPulseGenerator1 | The output source is set to Not Cam C Pulse Generator 1 - Applies to: CoaXPress. | |
TriggerOutSelectGPO0_NotCamCPulseGenerator2 | The output source is set to Not Cam C Pulse Generator 2 - Applies to: CoaXPress. | |
TriggerOutSelectGPO0_NotCamCPulseGenerator3 | The output source is set to Not Cam C Pulse Generator 3 - Applies to: CoaXPress. | |
TriggerOutSelectGPO0_NotCamDPulseGenerator0 | The output source is set to Not Cam D Pulse Generator 0 - Applies to: CoaXPress. | |
TriggerOutSelectGPO0_NotCamDPulseGenerator1 | The output source is set to Not Cam D Pulse Generator 1 - Applies to: CoaXPress. | |
TriggerOutSelectGPO0_NotCamDPulseGenerator2 | The output source is set to Not Cam D Pulse Generator 2 - Applies to: CoaXPress. | |
TriggerOutSelectGPO0_NotCamDPulseGenerator3 | The output source is set to Not Cam D Pulse Generator 3 - Applies to: CoaXPress. | |
TriggerOutSelectGPO0_NotPulseGenerator0 | Inverted signal of pulse generator 0 - Applies to: CoaXPress. | |
TriggerOutSelectGPO0_NotPulseGenerator1 | Inverted signal of pulse generator 1 - Applies to: CoaXPress. | |
TriggerOutSelectGPO0_NotPulseGenerator2 | Inverted signal of pulse generator 2 - Applies to: CoaXPress. | |
TriggerOutSelectGPO0_NotPulseGenerator3 | Inverted signal of pulse generator 3 - Applies to: CoaXPress. | |
TriggerOutSelectGPO0_PulseGenerator0 | The source for the output statistics is set to Pulse Generator 0 - Applies to: CoaXPress. | |
TriggerOutSelectGPO0_PulseGenerator1 | The source for the output statistics is set to Pulse Generator 1 - Applies to: CoaXPress. | |
TriggerOutSelectGPO0_PulseGenerator2 | The source for the output statistics is set to Pulse Generator 2 - Applies to: CoaXPress. | |
TriggerOutSelectGPO0_PulseGenerator3 | The source for the output statistics is set to Pulse Generator 3 - Applies to: CoaXPress. | |
TriggerOutSelectGPO0_VCC | A static one - Applies to: CoaXPress. |
Valid values for TriggerOutSelectGPO0.
enum TriggerOutSelectGPO1Enums#
Enumerator | Value | Description |
---|---|---|
TriggerOutSelectGPO1_BypassFrontGPI0 | Bypass the Front GPI 0 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO1_BypassFrontGPI1 | Bypass the Front GPI 1 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO1_BypassFrontGPI2 | Bypass the Front GPI 2 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO1_BypassFrontGPI3 | Bypass the Front GPI 3 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO1_BypassGPI0 | Bypass the GPI 0 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO1_BypassGPI1 | Bypass the GPI 1 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO1_BypassGPI2 | Bypass the GPI 2 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO1_BypassGPI3 | Bypass the GPI 3 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO1_BypassGPI4 | Bypass the GPI 4 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO1_BypassGPI5 | Bypass the GPI 5 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO1_BypassGPI6 | Bypass the GPI 6 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO1_BypassGPI7 | Bypass the GPI 7 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO1_CamAPulseGenerator0 | Camera port A Pulse Generator 0 - Applies to: CoaXPress. | |
TriggerOutSelectGPO1_CamAPulseGenerator1 | Camera port A Pulse Generator 1 - Applies to: CoaXPress. | |
TriggerOutSelectGPO1_CamAPulseGenerator2 | Camera port A Pulse Generator 2 - Applies to: CoaXPress. | |
TriggerOutSelectGPO1_CamAPulseGenerator3 | Camera port A Pulse Generator 3 - Applies to: CoaXPress. | |
TriggerOutSelectGPO1_CamBPulseGenerator0 | The output source is set to Cam B Pulse Generator 0 - Applies to: CoaXPress. | |
TriggerOutSelectGPO1_CamBPulseGenerator1 | The output source is set to Cam B Pulse Generator 1 - Applies to: CoaXPress. | |
TriggerOutSelectGPO1_CamBPulseGenerator2 | The output source is set to Cam B Pulse Generator 2 - Applies to: CoaXPress. | |
TriggerOutSelectGPO1_CamBPulseGenerator3 | The output source is set to Cam B Pulse Generator 3 - Applies to: CoaXPress. | |
TriggerOutSelectGPO1_CamCPulseGenerator0 | The output source is set to Cam C Pulse Generator 0 - Applies to: CoaXPress. | |
TriggerOutSelectGPO1_CamCPulseGenerator1 | The output source is set to Cam C Pulse Generator 1 - Applies to: CoaXPress. | |
TriggerOutSelectGPO1_CamCPulseGenerator2 | The output source is set to Cam C Pulse Generator 2 - Applies to: CoaXPress. | |
TriggerOutSelectGPO1_CamCPulseGenerator3 | The output source is set to Cam C Pulse Generator 3 - Applies to: CoaXPress. | |
TriggerOutSelectGPO1_CamDPulseGenerator0 | The output source is set to Cam D Pulse Generator 0 - Applies to: CoaXPress. | |
TriggerOutSelectGPO1_CamDPulseGenerator1 | The output source is set to Cam D Pulse Generator 1 - Applies to: CoaXPress. | |
TriggerOutSelectGPO1_CamDPulseGenerator2 | The output source is set to Cam D Pulse Generator 2 - Applies to: CoaXPress. | |
TriggerOutSelectGPO1_CamDPulseGenerator3 | The output source is set to Cam D Pulse Generator 3 - Applies to: CoaXPress. | |
TriggerOutSelectGPO1_GND | A static zero - Applies to: CoaXPress. | |
TriggerOutSelectGPO1_NotBypassFrontGPI0 | The output source is set to Not Bypass Front-GPI 0 - Applies to: CoaXPress. | |
TriggerOutSelectGPO1_NotBypassFrontGPI1 | The output source is set to Not Bypass Front-GPI 1 - Applies to: CoaXPress. | |
TriggerOutSelectGPO1_NotBypassFrontGPI2 | The output source is set to Not Bypass Front-GPI 2 - Applies to: CoaXPress. | |
TriggerOutSelectGPO1_NotBypassFrontGPI3 | The output source is set to Not Bypass Front-GPI 3 - Applies to: CoaXPress. | |
TriggerOutSelectGPO1_NotBypassGPI0 | Bypass the inverted GPI 0 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO1_NotBypassGPI1 | Bypass the inverted GPI 1 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO1_NotBypassGPI2 | Bypass the inverted GPI 2 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO1_NotBypassGPI3 | Bypass the inverted GPI 3 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO1_NotBypassGPI4 | Bypass the inverted GPI 4 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO1_NotBypassGPI5 | Bypass the inverted GPI 5 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO1_NotBypassGPI6 | Bypass the inverted GPI 6 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO1_NotBypassGPI7 | Bypass the inverted GPI 7 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO1_NotCamAPulseGenerator0 | Inverted signal of camera port A Pulse Generator 0 - Applies to: CoaXPress. | |
TriggerOutSelectGPO1_NotCamAPulseGenerator1 | Inverted signal of camera port A Pulse Generator 1 - Applies to: CoaXPress. | |
TriggerOutSelectGPO1_NotCamAPulseGenerator2 | Inverted signal of camera port A Pulse Generator 2 - Applies to: CoaXPress. | |
TriggerOutSelectGPO1_NotCamAPulseGenerator3 | Inverted signal of camera port A Pulse Generator 3 - Applies to: CoaXPress. | |
TriggerOutSelectGPO1_NotCamBPulseGenerator0 | The output source is set to Not Cam B Pulse Generator 0 - Applies to: CoaXPress. | |
TriggerOutSelectGPO1_NotCamBPulseGenerator1 | The output source is set to Not Cam B Pulse Generator 1 - Applies to: CoaXPress. | |
TriggerOutSelectGPO1_NotCamBPulseGenerator2 | The output source is set to Not Cam B Pulse Generator 2 - Applies to: CoaXPress. | |
TriggerOutSelectGPO1_NotCamBPulseGenerator3 | The output source is set to Not Cam B Pulse Generator 3 - Applies to: CoaXPress. | |
TriggerOutSelectGPO1_NotCamCPulseGenerator0 | The output source is set to Not Cam C Pulse Generator 0 - Applies to: CoaXPress. | |
TriggerOutSelectGPO1_NotCamCPulseGenerator1 | The output source is set to Not Cam C Pulse Generator 1 - Applies to: CoaXPress. | |
TriggerOutSelectGPO1_NotCamCPulseGenerator2 | The output source is set to Not Cam C Pulse Generator 2 - Applies to: CoaXPress. | |
TriggerOutSelectGPO1_NotCamCPulseGenerator3 | The output source is set to Not Cam C Pulse Generator 3 - Applies to: CoaXPress. | |
TriggerOutSelectGPO1_NotCamDPulseGenerator0 | The output source is set to Not Cam D Pulse Generator 0 - Applies to: CoaXPress. | |
TriggerOutSelectGPO1_NotCamDPulseGenerator1 | The output source is set to Not Cam D Pulse Generator 1 - Applies to: CoaXPress. | |
TriggerOutSelectGPO1_NotCamDPulseGenerator2 | The output source is set to Not Cam D Pulse Generator 2 - Applies to: CoaXPress. | |
TriggerOutSelectGPO1_NotCamDPulseGenerator3 | The output source is set to Not Cam D Pulse Generator 3 - Applies to: CoaXPress. | |
TriggerOutSelectGPO1_NotPulseGenerator0 | Inverted signal of pulse generator 0 - Applies to: CoaXPress. | |
TriggerOutSelectGPO1_NotPulseGenerator1 | Inverted signal of pulse generator 1 - Applies to: CoaXPress. | |
TriggerOutSelectGPO1_NotPulseGenerator2 | Inverted signal of pulse generator 2 - Applies to: CoaXPress. | |
TriggerOutSelectGPO1_NotPulseGenerator3 | Inverted signal of pulse generator 3 - Applies to: CoaXPress. | |
TriggerOutSelectGPO1_PulseGenerator0 | The source for the output statistics is set to Pulse Generator 0 - Applies to: CoaXPress. | |
TriggerOutSelectGPO1_PulseGenerator1 | The source for the output statistics is set to Pulse Generator 1 - Applies to: CoaXPress. | |
TriggerOutSelectGPO1_PulseGenerator2 | The source for the output statistics is set to Pulse Generator 2 - Applies to: CoaXPress. | |
TriggerOutSelectGPO1_PulseGenerator3 | The source for the output statistics is set to Pulse Generator 3 - Applies to: CoaXPress. | |
TriggerOutSelectGPO1_VCC | A static one - Applies to: CoaXPress. |
Valid values for TriggerOutSelectGPO1.
enum TriggerOutSelectGPO2Enums#
Enumerator | Value | Description |
---|---|---|
TriggerOutSelectGPO2_BypassFrontGPI0 | Bypass the Front GPI 0 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO2_BypassFrontGPI1 | Bypass the Front GPI 1 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO2_BypassFrontGPI2 | Bypass the Front GPI 2 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO2_BypassFrontGPI3 | Bypass the Front GPI 3 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO2_BypassGPI0 | Bypass the GPI 0 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO2_BypassGPI1 | Bypass the GPI 1 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO2_BypassGPI2 | Bypass the GPI 2 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO2_BypassGPI3 | Bypass the GPI 3 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO2_BypassGPI4 | Bypass the GPI 4 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO2_BypassGPI5 | Bypass the GPI 5 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO2_BypassGPI6 | Bypass the GPI 6 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO2_BypassGPI7 | Bypass the GPI 7 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO2_CamAPulseGenerator0 | Camera port A Pulse Generator 0 - Applies to: CoaXPress. | |
TriggerOutSelectGPO2_CamAPulseGenerator1 | Camera port A Pulse Generator 1 - Applies to: CoaXPress. | |
TriggerOutSelectGPO2_CamAPulseGenerator2 | Camera port A Pulse Generator 2 - Applies to: CoaXPress. | |
TriggerOutSelectGPO2_CamAPulseGenerator3 | Camera port A Pulse Generator 3 - Applies to: CoaXPress. | |
TriggerOutSelectGPO2_CamBPulseGenerator0 | The output source is set to Cam B Pulse Generator 0 - Applies to: CoaXPress. | |
TriggerOutSelectGPO2_CamBPulseGenerator1 | The output source is set to Cam B Pulse Generator 1 - Applies to: CoaXPress. | |
TriggerOutSelectGPO2_CamBPulseGenerator2 | The output source is set to Cam B Pulse Generator 2 - Applies to: CoaXPress. | |
TriggerOutSelectGPO2_CamBPulseGenerator3 | The output source is set to Cam B Pulse Generator 3 - Applies to: CoaXPress. | |
TriggerOutSelectGPO2_CamCPulseGenerator0 | The output source is set to Cam C Pulse Generator 0 - Applies to: CoaXPress. | |
TriggerOutSelectGPO2_CamCPulseGenerator1 | The output source is set to Cam C Pulse Generator 1 - Applies to: CoaXPress. | |
TriggerOutSelectGPO2_CamCPulseGenerator2 | The output source is set to Cam C Pulse Generator 2 - Applies to: CoaXPress. | |
TriggerOutSelectGPO2_CamCPulseGenerator3 | The output source is set to Cam C Pulse Generator 3 - Applies to: CoaXPress. | |
TriggerOutSelectGPO2_CamDPulseGenerator0 | The output source is set to Cam D Pulse Generator 0 - Applies to: CoaXPress. | |
TriggerOutSelectGPO2_CamDPulseGenerator1 | The output source is set to Cam D Pulse Generator 1 - Applies to: CoaXPress. | |
TriggerOutSelectGPO2_CamDPulseGenerator2 | The output source is set to Cam D Pulse Generator 2 - Applies to: CoaXPress. | |
TriggerOutSelectGPO2_CamDPulseGenerator3 | The output source is set to Cam D Pulse Generator 3 - Applies to: CoaXPress. | |
TriggerOutSelectGPO2_GND | A static zero - Applies to: CoaXPress. | |
TriggerOutSelectGPO2_NotBypassFrontGPI0 | The output source is set to Not Bypass Front-GPI 0 - Applies to: CoaXPress. | |
TriggerOutSelectGPO2_NotBypassFrontGPI1 | The output source is set to Not Bypass Front-GPI 1 - Applies to: CoaXPress. | |
TriggerOutSelectGPO2_NotBypassFrontGPI2 | The output source is set to Not Bypass Front-GPI 2 - Applies to: CoaXPress. | |
TriggerOutSelectGPO2_NotBypassFrontGPI3 | The output source is set to Not Bypass Front-GPI 3 - Applies to: CoaXPress. | |
TriggerOutSelectGPO2_NotBypassGPI0 | Bypass the inverted GPI 0 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO2_NotBypassGPI1 | Bypass the inverted GPI 1 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO2_NotBypassGPI2 | Bypass the inverted GPI 2 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO2_NotBypassGPI3 | Bypass the inverted GPI 3 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO2_NotBypassGPI4 | Bypass the inverted GPI 4 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO2_NotBypassGPI5 | Bypass the inverted GPI 5 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO2_NotBypassGPI6 | Bypass the inverted GPI 6 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO2_NotBypassGPI7 | Bypass the inverted GPI 7 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO2_NotCamAPulseGenerator0 | Inverted signal of camera port A Pulse Generator 0 - Applies to: CoaXPress. | |
TriggerOutSelectGPO2_NotCamAPulseGenerator1 | Inverted signal of camera port A Pulse Generator 1 - Applies to: CoaXPress. | |
TriggerOutSelectGPO2_NotCamAPulseGenerator2 | Inverted signal of camera port A Pulse Generator 2 - Applies to: CoaXPress. | |
TriggerOutSelectGPO2_NotCamAPulseGenerator3 | Inverted signal of camera port A Pulse Generator 3 - Applies to: CoaXPress. | |
TriggerOutSelectGPO2_NotCamBPulseGenerator0 | The output source is set to Not Cam B Pulse Generator 0 - Applies to: CoaXPress. | |
TriggerOutSelectGPO2_NotCamBPulseGenerator1 | The output source is set to Not Cam B Pulse Generator 1 - Applies to: CoaXPress. | |
TriggerOutSelectGPO2_NotCamBPulseGenerator2 | The output source is set to Not Cam B Pulse Generator 2 - Applies to: CoaXPress. | |
TriggerOutSelectGPO2_NotCamBPulseGenerator3 | The output source is set to Not Cam B Pulse Generator 3 - Applies to: CoaXPress. | |
TriggerOutSelectGPO2_NotCamCPulseGenerator0 | The output source is set to Not Cam C Pulse Generator 0 - Applies to: CoaXPress. | |
TriggerOutSelectGPO2_NotCamCPulseGenerator1 | The output source is set to Not Cam C Pulse Generator 1 - Applies to: CoaXPress. | |
TriggerOutSelectGPO2_NotCamCPulseGenerator2 | The output source is set to Not Cam C Pulse Generator 2 - Applies to: CoaXPress. | |
TriggerOutSelectGPO2_NotCamCPulseGenerator3 | The output source is set to Not Cam C Pulse Generator 3 - Applies to: CoaXPress. | |
TriggerOutSelectGPO2_NotCamDPulseGenerator0 | The output source is set to Not Cam D Pulse Generator 0 - Applies to: CoaXPress. | |
TriggerOutSelectGPO2_NotCamDPulseGenerator1 | The output source is set to Not Cam D Pulse Generator 1 - Applies to: CoaXPress. | |
TriggerOutSelectGPO2_NotCamDPulseGenerator2 | The output source is set to Not Cam D Pulse Generator 2 - Applies to: CoaXPress. | |
TriggerOutSelectGPO2_NotCamDPulseGenerator3 | The output source is set to Not Cam D Pulse Generator 3 - Applies to: CoaXPress. | |
TriggerOutSelectGPO2_NotPulseGenerator0 | Inverted signal of pulse generator 0 - Applies to: CoaXPress. | |
TriggerOutSelectGPO2_NotPulseGenerator1 | Inverted signal of pulse generator 1 - Applies to: CoaXPress. | |
TriggerOutSelectGPO2_NotPulseGenerator2 | Inverted signal of pulse generator 2 - Applies to: CoaXPress. | |
TriggerOutSelectGPO2_NotPulseGenerator3 | Inverted signal of pulse generator 3 - Applies to: CoaXPress. | |
TriggerOutSelectGPO2_PulseGenerator0 | The source for the output statistics is set to Pulse Generator 0 - Applies to: CoaXPress. | |
TriggerOutSelectGPO2_PulseGenerator1 | The source for the output statistics is set to Pulse Generator 1 - Applies to: CoaXPress. | |
TriggerOutSelectGPO2_PulseGenerator2 | The source for the output statistics is set to Pulse Generator 2 - Applies to: CoaXPress. | |
TriggerOutSelectGPO2_PulseGenerator3 | The source for the output statistics is set to Pulse Generator 3 - Applies to: CoaXPress. | |
TriggerOutSelectGPO2_VCC | A static one - Applies to: CoaXPress. |
Valid values for TriggerOutSelectGPO2.
enum TriggerOutSelectGPO3Enums#
Enumerator | Value | Description |
---|---|---|
TriggerOutSelectGPO3_BypassFrontGPI0 | Bypass the Front GPI 0 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO3_BypassFrontGPI1 | Bypass the Front GPI 1 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO3_BypassFrontGPI2 | Bypass the Front GPI 2 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO3_BypassFrontGPI3 | Bypass the Front GPI 3 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO3_BypassGPI0 | Bypass the GPI 0 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO3_BypassGPI1 | Bypass the GPI 1 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO3_BypassGPI2 | Bypass the GPI 2 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO3_BypassGPI3 | Bypass the GPI 3 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO3_BypassGPI4 | Bypass the GPI 4 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO3_BypassGPI5 | Bypass the GPI 5 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO3_BypassGPI6 | Bypass the GPI 6 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO3_BypassGPI7 | Bypass the GPI 7 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO3_CamAPulseGenerator0 | Camera port A Pulse Generator 0 - Applies to: CoaXPress. | |
TriggerOutSelectGPO3_CamAPulseGenerator1 | Camera port A Pulse Generator 1 - Applies to: CoaXPress. | |
TriggerOutSelectGPO3_CamAPulseGenerator2 | Camera port A Pulse Generator 2 - Applies to: CoaXPress. | |
TriggerOutSelectGPO3_CamAPulseGenerator3 | Camera port A Pulse Generator 3 - Applies to: CoaXPress. | |
TriggerOutSelectGPO3_CamBPulseGenerator0 | The output source is set to Cam B Pulse Generator 0 - Applies to: CoaXPress. | |
TriggerOutSelectGPO3_CamBPulseGenerator1 | The output source is set to Cam B Pulse Generator 1 - Applies to: CoaXPress. | |
TriggerOutSelectGPO3_CamBPulseGenerator2 | The output source is set to Cam B Pulse Generator 2 - Applies to: CoaXPress. | |
TriggerOutSelectGPO3_CamBPulseGenerator3 | The output source is set to Cam B Pulse Generator 3 - Applies to: CoaXPress. | |
TriggerOutSelectGPO3_CamCPulseGenerator0 | The output source is set to Cam C Pulse Generator 0 - Applies to: CoaXPress. | |
TriggerOutSelectGPO3_CamCPulseGenerator1 | The output source is set to Cam C Pulse Generator 1 - Applies to: CoaXPress. | |
TriggerOutSelectGPO3_CamCPulseGenerator2 | The output source is set to Cam C Pulse Generator 2 - Applies to: CoaXPress. | |
TriggerOutSelectGPO3_CamCPulseGenerator3 | The output source is set to Cam C Pulse Generator 3 - Applies to: CoaXPress. | |
TriggerOutSelectGPO3_CamDPulseGenerator0 | The output source is set to Cam D Pulse Generator 0 - Applies to: CoaXPress. | |
TriggerOutSelectGPO3_CamDPulseGenerator1 | The output source is set to Cam D Pulse Generator 1 - Applies to: CoaXPress. | |
TriggerOutSelectGPO3_CamDPulseGenerator2 | The output source is set to Cam D Pulse Generator 2 - Applies to: CoaXPress. | |
TriggerOutSelectGPO3_CamDPulseGenerator3 | The output source is set to Cam D Pulse Generator 3 - Applies to: CoaXPress. | |
TriggerOutSelectGPO3_GND | A static zero - Applies to: CoaXPress. | |
TriggerOutSelectGPO3_NotBypassFrontGPI0 | The output source is set to Not Bypass Front-GPI 0 - Applies to: CoaXPress. | |
TriggerOutSelectGPO3_NotBypassFrontGPI1 | The output source is set to Not Bypass Front-GPI 1 - Applies to: CoaXPress. | |
TriggerOutSelectGPO3_NotBypassFrontGPI2 | The output source is set to Not Bypass Front-GPI 2 - Applies to: CoaXPress. | |
TriggerOutSelectGPO3_NotBypassFrontGPI3 | The output source is set to Not Bypass Front-GPI 3 - Applies to: CoaXPress. | |
TriggerOutSelectGPO3_NotBypassGPI0 | Bypass the inverted GPI 0 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO3_NotBypassGPI1 | Bypass the inverted GPI 1 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO3_NotBypassGPI2 | Bypass the inverted GPI 2 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO3_NotBypassGPI3 | Bypass the inverted GPI 3 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO3_NotBypassGPI4 | Bypass the inverted GPI 4 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO3_NotBypassGPI5 | Bypass the inverted GPI 5 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO3_NotBypassGPI6 | Bypass the inverted GPI 6 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO3_NotBypassGPI7 | Bypass the inverted GPI 7 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO3_NotCamAPulseGenerator0 | Inverted signal of camera port A Pulse Generator 0 - Applies to: CoaXPress. | |
TriggerOutSelectGPO3_NotCamAPulseGenerator1 | Inverted signal of camera port A Pulse Generator 1 - Applies to: CoaXPress. | |
TriggerOutSelectGPO3_NotCamAPulseGenerator2 | Inverted signal of camera port A Pulse Generator 2 - Applies to: CoaXPress. | |
TriggerOutSelectGPO3_NotCamAPulseGenerator3 | Inverted signal of camera port A Pulse Generator 3 - Applies to: CoaXPress. | |
TriggerOutSelectGPO3_NotCamBPulseGenerator0 | The output source is set to Not Cam B Pulse Generator 0 - Applies to: CoaXPress. | |
TriggerOutSelectGPO3_NotCamBPulseGenerator1 | The output source is set to Not Cam B Pulse Generator 1 - Applies to: CoaXPress. | |
TriggerOutSelectGPO3_NotCamBPulseGenerator2 | The output source is set to Not Cam B Pulse Generator 2 - Applies to: CoaXPress. | |
TriggerOutSelectGPO3_NotCamBPulseGenerator3 | The output source is set to Not Cam B Pulse Generator 3 - Applies to: CoaXPress. | |
TriggerOutSelectGPO3_NotCamCPulseGenerator0 | The output source is set to Not Cam C Pulse Generator 0 - Applies to: CoaXPress. | |
TriggerOutSelectGPO3_NotCamCPulseGenerator1 | The output source is set to Not Cam C Pulse Generator 1 - Applies to: CoaXPress. | |
TriggerOutSelectGPO3_NotCamCPulseGenerator2 | The output source is set to Not Cam C Pulse Generator 2 - Applies to: CoaXPress. | |
TriggerOutSelectGPO3_NotCamCPulseGenerator3 | The output source is set to Not Cam C Pulse Generator 3 - Applies to: CoaXPress. | |
TriggerOutSelectGPO3_NotCamDPulseGenerator0 | The output source is set to Not Cam D Pulse Generator 0 - Applies to: CoaXPress. | |
TriggerOutSelectGPO3_NotCamDPulseGenerator1 | The output source is set to Not Cam D Pulse Generator 1 - Applies to: CoaXPress. | |
TriggerOutSelectGPO3_NotCamDPulseGenerator2 | The output source is set to Not Cam D Pulse Generator 2 - Applies to: CoaXPress. | |
TriggerOutSelectGPO3_NotCamDPulseGenerator3 | The output source is set to Not Cam D Pulse Generator 3 - Applies to: CoaXPress. | |
TriggerOutSelectGPO3_NotPulseGenerator0 | Inverted signal of pulse generator 0 - Applies to: CoaXPress. | |
TriggerOutSelectGPO3_NotPulseGenerator1 | Inverted signal of pulse generator 1 - Applies to: CoaXPress. | |
TriggerOutSelectGPO3_NotPulseGenerator2 | Inverted signal of pulse generator 2 - Applies to: CoaXPress. | |
TriggerOutSelectGPO3_NotPulseGenerator3 | Inverted signal of pulse generator 3 - Applies to: CoaXPress. | |
TriggerOutSelectGPO3_PulseGenerator0 | The source for the output statistics is set to Pulse Generator 0 - Applies to: CoaXPress. | |
TriggerOutSelectGPO3_PulseGenerator1 | The source for the output statistics is set to Pulse Generator 1 - Applies to: CoaXPress. | |
TriggerOutSelectGPO3_PulseGenerator2 | The source for the output statistics is set to Pulse Generator 2 - Applies to: CoaXPress. | |
TriggerOutSelectGPO3_PulseGenerator3 | The source for the output statistics is set to Pulse Generator 3 - Applies to: CoaXPress. | |
TriggerOutSelectGPO3_VCC | A static one - Applies to: CoaXPress. |
Valid values for TriggerOutSelectGPO3.
enum TriggerOutSelectGPO4Enums#
Enumerator | Value | Description |
---|---|---|
TriggerOutSelectGPO4_BypassFrontGPI0 | Bypass the Front GPI 0 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO4_BypassFrontGPI1 | Bypass the Front GPI 1 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO4_BypassFrontGPI2 | Bypass the Front GPI 2 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO4_BypassFrontGPI3 | Bypass the Front GPI 3 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO4_BypassGPI0 | Bypass the GPI 0 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO4_BypassGPI1 | Bypass the GPI 1 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO4_BypassGPI2 | Bypass the GPI 2 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO4_BypassGPI3 | Bypass the GPI 3 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO4_BypassGPI4 | Bypass the GPI 4 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO4_BypassGPI5 | Bypass the GPI 5 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO4_BypassGPI6 | Bypass the GPI 6 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO4_BypassGPI7 | Bypass the GPI 7 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO4_CamAPulseGenerator0 | Camera port A Pulse Generator 0 - Applies to: CoaXPress. | |
TriggerOutSelectGPO4_CamAPulseGenerator1 | Camera port A Pulse Generator 1 - Applies to: CoaXPress. | |
TriggerOutSelectGPO4_CamAPulseGenerator2 | Camera port A Pulse Generator 2 - Applies to: CoaXPress. | |
TriggerOutSelectGPO4_CamAPulseGenerator3 | Camera port A Pulse Generator 3 - Applies to: CoaXPress. | |
TriggerOutSelectGPO4_CamBPulseGenerator0 | The output source is set to Cam B Pulse Generator 0 - Applies to: CoaXPress. | |
TriggerOutSelectGPO4_CamBPulseGenerator1 | The output source is set to Cam B Pulse Generator 1 - Applies to: CoaXPress. | |
TriggerOutSelectGPO4_CamBPulseGenerator2 | The output source is set to Cam B Pulse Generator 2 - Applies to: CoaXPress. | |
TriggerOutSelectGPO4_CamBPulseGenerator3 | The output source is set to Cam B Pulse Generator 3 - Applies to: CoaXPress. | |
TriggerOutSelectGPO4_CamCPulseGenerator0 | The output source is set to Cam C Pulse Generator 0 - Applies to: CoaXPress. | |
TriggerOutSelectGPO4_CamCPulseGenerator1 | The output source is set to Cam C Pulse Generator 1 - Applies to: CoaXPress. | |
TriggerOutSelectGPO4_CamCPulseGenerator2 | The output source is set to Cam C Pulse Generator 2 - Applies to: CoaXPress. | |
TriggerOutSelectGPO4_CamCPulseGenerator3 | The output source is set to Cam C Pulse Generator 3 - Applies to: CoaXPress. | |
TriggerOutSelectGPO4_CamDPulseGenerator0 | The output source is set to Cam D Pulse Generator 0 - Applies to: CoaXPress. | |
TriggerOutSelectGPO4_CamDPulseGenerator1 | The output source is set to Cam D Pulse Generator 1 - Applies to: CoaXPress. | |
TriggerOutSelectGPO4_CamDPulseGenerator2 | The output source is set to Cam D Pulse Generator 2 - Applies to: CoaXPress. | |
TriggerOutSelectGPO4_CamDPulseGenerator3 | The output source is set to Cam D Pulse Generator 3 - Applies to: CoaXPress. | |
TriggerOutSelectGPO4_GND | A static zero - Applies to: CoaXPress. | |
TriggerOutSelectGPO4_NotBypassFrontGPI0 | The output source is set to Not Bypass Front-GPI 0 - Applies to: CoaXPress. | |
TriggerOutSelectGPO4_NotBypassFrontGPI1 | The output source is set to Not Bypass Front-GPI 1 - Applies to: CoaXPress. | |
TriggerOutSelectGPO4_NotBypassFrontGPI2 | The output source is set to Not Bypass Front-GPI 2 - Applies to: CoaXPress. | |
TriggerOutSelectGPO4_NotBypassFrontGPI3 | The output source is set to Not Bypass Front-GPI 3 - Applies to: CoaXPress. | |
TriggerOutSelectGPO4_NotBypassGPI0 | Bypass the inverted GPI 0 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO4_NotBypassGPI1 | Bypass the inverted GPI 1 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO4_NotBypassGPI2 | Bypass the inverted GPI 2 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO4_NotBypassGPI3 | Bypass the inverted GPI 3 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO4_NotBypassGPI4 | Bypass the inverted GPI 4 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO4_NotBypassGPI5 | Bypass the inverted GPI 5 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO4_NotBypassGPI6 | Bypass the inverted GPI 6 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO4_NotBypassGPI7 | Bypass the inverted GPI 7 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO4_NotCamAPulseGenerator0 | Inverted signal of camera port A Pulse Generator 0 - Applies to: CoaXPress. | |
TriggerOutSelectGPO4_NotCamAPulseGenerator1 | Inverted signal of camera port A Pulse Generator 1 - Applies to: CoaXPress. | |
TriggerOutSelectGPO4_NotCamAPulseGenerator2 | Inverted signal of camera port A Pulse Generator 2 - Applies to: CoaXPress. | |
TriggerOutSelectGPO4_NotCamAPulseGenerator3 | Inverted signal of camera port A Pulse Generator 3 - Applies to: CoaXPress. | |
TriggerOutSelectGPO4_NotCamBPulseGenerator0 | The output source is set to Not Cam B Pulse Generator 0 - Applies to: CoaXPress. | |
TriggerOutSelectGPO4_NotCamBPulseGenerator1 | The output source is set to Not Cam B Pulse Generator 1 - Applies to: CoaXPress. | |
TriggerOutSelectGPO4_NotCamBPulseGenerator2 | The output source is set to Not Cam B Pulse Generator 2 - Applies to: CoaXPress. | |
TriggerOutSelectGPO4_NotCamBPulseGenerator3 | The output source is set to Not Cam B Pulse Generator 3 - Applies to: CoaXPress. | |
TriggerOutSelectGPO4_NotCamCPulseGenerator0 | The output source is set to Not Cam C Pulse Generator 0 - Applies to: CoaXPress. | |
TriggerOutSelectGPO4_NotCamCPulseGenerator1 | The output source is set to Not Cam C Pulse Generator 1 - Applies to: CoaXPress. | |
TriggerOutSelectGPO4_NotCamCPulseGenerator2 | The output source is set to Not Cam C Pulse Generator 2 - Applies to: CoaXPress. | |
TriggerOutSelectGPO4_NotCamCPulseGenerator3 | The output source is set to Not Cam C Pulse Generator 3 - Applies to: CoaXPress. | |
TriggerOutSelectGPO4_NotCamDPulseGenerator0 | The output source is set to Not Cam D Pulse Generator 0 - Applies to: CoaXPress. | |
TriggerOutSelectGPO4_NotCamDPulseGenerator1 | The output source is set to Not Cam D Pulse Generator 1 - Applies to: CoaXPress. | |
TriggerOutSelectGPO4_NotCamDPulseGenerator2 | The output source is set to Not Cam D Pulse Generator 2 - Applies to: CoaXPress. | |
TriggerOutSelectGPO4_NotCamDPulseGenerator3 | The output source is set to Not Cam D Pulse Generator 3 - Applies to: CoaXPress. | |
TriggerOutSelectGPO4_NotPulseGenerator0 | Inverted signal of pulse generator 0 - Applies to: CoaXPress. | |
TriggerOutSelectGPO4_NotPulseGenerator1 | Inverted signal of pulse generator 1 - Applies to: CoaXPress. | |
TriggerOutSelectGPO4_NotPulseGenerator2 | Inverted signal of pulse generator 2 - Applies to: CoaXPress. | |
TriggerOutSelectGPO4_NotPulseGenerator3 | Inverted signal of pulse generator 3 - Applies to: CoaXPress. | |
TriggerOutSelectGPO4_PulseGenerator0 | The source for the output statistics is set to Pulse Generator 0 - Applies to: CoaXPress. | |
TriggerOutSelectGPO4_PulseGenerator1 | The source for the output statistics is set to Pulse Generator 1 - Applies to: CoaXPress. | |
TriggerOutSelectGPO4_PulseGenerator2 | The source for the output statistics is set to Pulse Generator 2 - Applies to: CoaXPress. | |
TriggerOutSelectGPO4_PulseGenerator3 | The source for the output statistics is set to Pulse Generator 3 - Applies to: CoaXPress. | |
TriggerOutSelectGPO4_VCC | A static one - Applies to: CoaXPress. |
Valid values for TriggerOutSelectGPO4.
enum TriggerOutSelectGPO5Enums#
Enumerator | Value | Description |
---|---|---|
TriggerOutSelectGPO5_BypassFrontGPI0 | Bypass the Front GPI 0 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO5_BypassFrontGPI1 | Bypass the Front GPI 1 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO5_BypassFrontGPI2 | Bypass the Front GPI 2 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO5_BypassFrontGPI3 | Bypass the Front GPI 3 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO5_BypassGPI0 | Bypass the GPI 0 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO5_BypassGPI1 | Bypass the GPI 1 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO5_BypassGPI2 | Bypass the GPI 2 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO5_BypassGPI3 | Bypass the GPI 3 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO5_BypassGPI4 | Bypass the GPI 4 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO5_BypassGPI5 | Bypass the GPI 5 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO5_BypassGPI6 | Bypass the GPI 6 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO5_BypassGPI7 | Bypass the GPI 7 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO5_CamAPulseGenerator0 | Camera port A Pulse Generator 0 - Applies to: CoaXPress. | |
TriggerOutSelectGPO5_CamAPulseGenerator1 | Camera port A Pulse Generator 1 - Applies to: CoaXPress. | |
TriggerOutSelectGPO5_CamAPulseGenerator2 | Camera port A Pulse Generator 2 - Applies to: CoaXPress. | |
TriggerOutSelectGPO5_CamAPulseGenerator3 | Camera port A Pulse Generator 3 - Applies to: CoaXPress. | |
TriggerOutSelectGPO5_CamBPulseGenerator0 | The output source is set to Cam B Pulse Generator 0 - Applies to: CoaXPress. | |
TriggerOutSelectGPO5_CamBPulseGenerator1 | The output source is set to Cam B Pulse Generator 1 - Applies to: CoaXPress. | |
TriggerOutSelectGPO5_CamBPulseGenerator2 | The output source is set to Cam B Pulse Generator 2 - Applies to: CoaXPress. | |
TriggerOutSelectGPO5_CamBPulseGenerator3 | The output source is set to Cam B Pulse Generator 3 - Applies to: CoaXPress. | |
TriggerOutSelectGPO5_CamCPulseGenerator0 | The output source is set to Cam C Pulse Generator 0 - Applies to: CoaXPress. | |
TriggerOutSelectGPO5_CamCPulseGenerator1 | The output source is set to Cam C Pulse Generator 1 - Applies to: CoaXPress. | |
TriggerOutSelectGPO5_CamCPulseGenerator2 | The output source is set to Cam C Pulse Generator 2 - Applies to: CoaXPress. | |
TriggerOutSelectGPO5_CamCPulseGenerator3 | The output source is set to Cam C Pulse Generator 3 - Applies to: CoaXPress. | |
TriggerOutSelectGPO5_CamDPulseGenerator0 | The output source is set to Cam D Pulse Generator 0 - Applies to: CoaXPress. | |
TriggerOutSelectGPO5_CamDPulseGenerator1 | The output source is set to Cam D Pulse Generator 1 - Applies to: CoaXPress. | |
TriggerOutSelectGPO5_CamDPulseGenerator2 | The output source is set to Cam D Pulse Generator 2 - Applies to: CoaXPress. | |
TriggerOutSelectGPO5_CamDPulseGenerator3 | The output source is set to Cam D Pulse Generator 3 - Applies to: CoaXPress. | |
TriggerOutSelectGPO5_GND | A static zero - Applies to: CoaXPress. | |
TriggerOutSelectGPO5_NotBypassFrontGPI0 | The output source is set to Not Bypass Front-GPI 0 - Applies to: CoaXPress. | |
TriggerOutSelectGPO5_NotBypassFrontGPI1 | The output source is set to Not Bypass Front-GPI 1 - Applies to: CoaXPress. | |
TriggerOutSelectGPO5_NotBypassFrontGPI2 | The output source is set to Not Bypass Front-GPI 2 - Applies to: CoaXPress. | |
TriggerOutSelectGPO5_NotBypassFrontGPI3 | The output source is set to Not Bypass Front-GPI 3 - Applies to: CoaXPress. | |
TriggerOutSelectGPO5_NotBypassGPI0 | Bypass the inverted GPI 0 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO5_NotBypassGPI1 | Bypass the inverted GPI 1 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO5_NotBypassGPI2 | Bypass the inverted GPI 2 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO5_NotBypassGPI3 | Bypass the inverted GPI 3 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO5_NotBypassGPI4 | Bypass the inverted GPI 4 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO5_NotBypassGPI5 | Bypass the inverted GPI 5 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO5_NotBypassGPI6 | Bypass the inverted GPI 6 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO5_NotBypassGPI7 | Bypass the inverted GPI 7 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO5_NotCamAPulseGenerator0 | Inverted signal of camera port A Pulse Generator 0 - Applies to: CoaXPress. | |
TriggerOutSelectGPO5_NotCamAPulseGenerator1 | Inverted signal of camera port A Pulse Generator 1 - Applies to: CoaXPress. | |
TriggerOutSelectGPO5_NotCamAPulseGenerator2 | Inverted signal of camera port A Pulse Generator 2 - Applies to: CoaXPress. | |
TriggerOutSelectGPO5_NotCamAPulseGenerator3 | Inverted signal of camera port A Pulse Generator 3 - Applies to: CoaXPress. | |
TriggerOutSelectGPO5_NotCamBPulseGenerator0 | The output source is set to Not Cam B Pulse Generator 0 - Applies to: CoaXPress. | |
TriggerOutSelectGPO5_NotCamBPulseGenerator1 | The output source is set to Not Cam B Pulse Generator 1 - Applies to: CoaXPress. | |
TriggerOutSelectGPO5_NotCamBPulseGenerator2 | The output source is set to Not Cam B Pulse Generator 2 - Applies to: CoaXPress. | |
TriggerOutSelectGPO5_NotCamBPulseGenerator3 | The output source is set to Not Cam B Pulse Generator 3 - Applies to: CoaXPress. | |
TriggerOutSelectGPO5_NotCamCPulseGenerator0 | The output source is set to Not Cam C Pulse Generator 0 - Applies to: CoaXPress. | |
TriggerOutSelectGPO5_NotCamCPulseGenerator1 | The output source is set to Not Cam C Pulse Generator 1 - Applies to: CoaXPress. | |
TriggerOutSelectGPO5_NotCamCPulseGenerator2 | The output source is set to Not Cam C Pulse Generator 2 - Applies to: CoaXPress. | |
TriggerOutSelectGPO5_NotCamCPulseGenerator3 | The output source is set to Not Cam C Pulse Generator 3 - Applies to: CoaXPress. | |
TriggerOutSelectGPO5_NotCamDPulseGenerator0 | The output source is set to Not Cam D Pulse Generator 0 - Applies to: CoaXPress. | |
TriggerOutSelectGPO5_NotCamDPulseGenerator1 | The output source is set to Not Cam D Pulse Generator 1 - Applies to: CoaXPress. | |
TriggerOutSelectGPO5_NotCamDPulseGenerator2 | The output source is set to Not Cam D Pulse Generator 2 - Applies to: CoaXPress. | |
TriggerOutSelectGPO5_NotCamDPulseGenerator3 | The output source is set to Not Cam D Pulse Generator 3 - Applies to: CoaXPress. | |
TriggerOutSelectGPO5_NotPulseGenerator0 | Inverted signal of pulse generator 0 - Applies to: CoaXPress. | |
TriggerOutSelectGPO5_NotPulseGenerator1 | Inverted signal of pulse generator 1 - Applies to: CoaXPress. | |
TriggerOutSelectGPO5_NotPulseGenerator2 | Inverted signal of pulse generator 2 - Applies to: CoaXPress. | |
TriggerOutSelectGPO5_NotPulseGenerator3 | Inverted signal of pulse generator 3 - Applies to: CoaXPress. | |
TriggerOutSelectGPO5_PulseGenerator0 | The source for the output statistics is set to Pulse Generator 0 - Applies to: CoaXPress. | |
TriggerOutSelectGPO5_PulseGenerator1 | The source for the output statistics is set to Pulse Generator 1 - Applies to: CoaXPress. | |
TriggerOutSelectGPO5_PulseGenerator2 | The source for the output statistics is set to Pulse Generator 2 - Applies to: CoaXPress. | |
TriggerOutSelectGPO5_PulseGenerator3 | The source for the output statistics is set to Pulse Generator 3 - Applies to: CoaXPress. | |
TriggerOutSelectGPO5_VCC | A static one - Applies to: CoaXPress. |
Valid values for TriggerOutSelectGPO5.
enum TriggerOutSelectGPO6Enums#
Enumerator | Value | Description |
---|---|---|
TriggerOutSelectGPO6_BypassFrontGPI0 | Bypass the Front GPI 0 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO6_BypassFrontGPI1 | Bypass the Front GPI 1 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO6_BypassFrontGPI2 | Bypass the Front GPI 2 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO6_BypassFrontGPI3 | Bypass the Front GPI 3 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO6_BypassGPI0 | Bypass the GPI 0 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO6_BypassGPI1 | Bypass the GPI 1 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO6_BypassGPI2 | Bypass the GPI 2 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO6_BypassGPI3 | Bypass the GPI 3 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO6_BypassGPI4 | Bypass the GPI 4 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO6_BypassGPI5 | Bypass the GPI 5 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO6_BypassGPI6 | Bypass the GPI 6 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO6_BypassGPI7 | Bypass the GPI 7 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO6_CamAPulseGenerator0 | Camera port A Pulse Generator 0 - Applies to: CoaXPress. | |
TriggerOutSelectGPO6_CamAPulseGenerator1 | Camera port A Pulse Generator 1 - Applies to: CoaXPress. | |
TriggerOutSelectGPO6_CamAPulseGenerator2 | Camera port A Pulse Generator 2 - Applies to: CoaXPress. | |
TriggerOutSelectGPO6_CamAPulseGenerator3 | Camera port A Pulse Generator 3 - Applies to: CoaXPress. | |
TriggerOutSelectGPO6_CamBPulseGenerator0 | The output source is set to Cam B Pulse Generator 0 - Applies to: CoaXPress. | |
TriggerOutSelectGPO6_CamBPulseGenerator1 | The output source is set to Cam B Pulse Generator 1 - Applies to: CoaXPress. | |
TriggerOutSelectGPO6_CamBPulseGenerator2 | The output source is set to Cam B Pulse Generator 2 - Applies to: CoaXPress. | |
TriggerOutSelectGPO6_CamBPulseGenerator3 | The output source is set to Cam B Pulse Generator 3 - Applies to: CoaXPress. | |
TriggerOutSelectGPO6_CamCPulseGenerator0 | The output source is set to Cam C Pulse Generator 0 - Applies to: CoaXPress. | |
TriggerOutSelectGPO6_CamCPulseGenerator1 | The output source is set to Cam C Pulse Generator 1 - Applies to: CoaXPress. | |
TriggerOutSelectGPO6_CamCPulseGenerator2 | The output source is set to Cam C Pulse Generator 2 - Applies to: CoaXPress. | |
TriggerOutSelectGPO6_CamCPulseGenerator3 | The output source is set to Cam C Pulse Generator 3 - Applies to: CoaXPress. | |
TriggerOutSelectGPO6_CamDPulseGenerator0 | The output source is set to Cam D Pulse Generator 0 - Applies to: CoaXPress. | |
TriggerOutSelectGPO6_CamDPulseGenerator1 | The output source is set to Cam D Pulse Generator 1 - Applies to: CoaXPress. | |
TriggerOutSelectGPO6_CamDPulseGenerator2 | The output source is set to Cam D Pulse Generator 2 - Applies to: CoaXPress. | |
TriggerOutSelectGPO6_CamDPulseGenerator3 | The output source is set to Cam D Pulse Generator 3 - Applies to: CoaXPress. | |
TriggerOutSelectGPO6_GND | A static zero - Applies to: CoaXPress. | |
TriggerOutSelectGPO6_NotBypassFrontGPI0 | The output source is set to Not Bypass Front-GPI 0 - Applies to: CoaXPress. | |
TriggerOutSelectGPO6_NotBypassFrontGPI1 | The output source is set to Not Bypass Front-GPI 1 - Applies to: CoaXPress. | |
TriggerOutSelectGPO6_NotBypassFrontGPI2 | The output source is set to Not Bypass Front-GPI 2 - Applies to: CoaXPress. | |
TriggerOutSelectGPO6_NotBypassFrontGPI3 | The output source is set to Not Bypass Front-GPI 3 - Applies to: CoaXPress. | |
TriggerOutSelectGPO6_NotBypassGPI0 | Bypass the inverted GPI 0 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO6_NotBypassGPI1 | Bypass the inverted GPI 1 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO6_NotBypassGPI2 | Bypass the inverted GPI 2 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO6_NotBypassGPI3 | Bypass the inverted GPI 3 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO6_NotBypassGPI4 | Bypass the inverted GPI 4 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO6_NotBypassGPI5 | Bypass the inverted GPI 5 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO6_NotBypassGPI6 | Bypass the inverted GPI 6 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO6_NotBypassGPI7 | Bypass the inverted GPI 7 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO6_NotCamAPulseGenerator0 | Inverted signal of camera port A Pulse Generator 0 - Applies to: CoaXPress. | |
TriggerOutSelectGPO6_NotCamAPulseGenerator1 | Inverted signal of camera port A Pulse Generator 1 - Applies to: CoaXPress. | |
TriggerOutSelectGPO6_NotCamAPulseGenerator2 | Inverted signal of camera port A Pulse Generator 2 - Applies to: CoaXPress. | |
TriggerOutSelectGPO6_NotCamAPulseGenerator3 | Inverted signal of camera port A Pulse Generator 3 - Applies to: CoaXPress. | |
TriggerOutSelectGPO6_NotCamBPulseGenerator0 | The output source is set to Not Cam B Pulse Generator 0 - Applies to: CoaXPress. | |
TriggerOutSelectGPO6_NotCamBPulseGenerator1 | The output source is set to Not Cam B Pulse Generator 1 - Applies to: CoaXPress. | |
TriggerOutSelectGPO6_NotCamBPulseGenerator2 | The output source is set to Not Cam B Pulse Generator 2 - Applies to: CoaXPress. | |
TriggerOutSelectGPO6_NotCamBPulseGenerator3 | The output source is set to Not Cam B Pulse Generator 3 - Applies to: CoaXPress. | |
TriggerOutSelectGPO6_NotCamCPulseGenerator0 | The output source is set to Not Cam C Pulse Generator 0 - Applies to: CoaXPress. | |
TriggerOutSelectGPO6_NotCamCPulseGenerator1 | The output source is set to Not Cam C Pulse Generator 1 - Applies to: CoaXPress. | |
TriggerOutSelectGPO6_NotCamCPulseGenerator2 | The output source is set to Not Cam C Pulse Generator 2 - Applies to: CoaXPress. | |
TriggerOutSelectGPO6_NotCamCPulseGenerator3 | The output source is set to Not Cam C Pulse Generator 3 - Applies to: CoaXPress. | |
TriggerOutSelectGPO6_NotCamDPulseGenerator0 | The output source is set to Not Cam D Pulse Generator 0 - Applies to: CoaXPress. | |
TriggerOutSelectGPO6_NotCamDPulseGenerator1 | The output source is set to Not Cam D Pulse Generator 1 - Applies to: CoaXPress. | |
TriggerOutSelectGPO6_NotCamDPulseGenerator2 | The output source is set to Not Cam D Pulse Generator 2 - Applies to: CoaXPress. | |
TriggerOutSelectGPO6_NotCamDPulseGenerator3 | The output source is set to Not Cam D Pulse Generator 3 - Applies to: CoaXPress. | |
TriggerOutSelectGPO6_NotPulseGenerator0 | Inverted signal of pulse generator 0 - Applies to: CoaXPress. | |
TriggerOutSelectGPO6_NotPulseGenerator1 | Inverted signal of pulse generator 1 - Applies to: CoaXPress. | |
TriggerOutSelectGPO6_NotPulseGenerator2 | Inverted signal of pulse generator 2 - Applies to: CoaXPress. | |
TriggerOutSelectGPO6_NotPulseGenerator3 | Inverted signal of pulse generator 3 - Applies to: CoaXPress. | |
TriggerOutSelectGPO6_PulseGenerator0 | The source for the output statistics is set to Pulse Generator 0 - Applies to: CoaXPress. | |
TriggerOutSelectGPO6_PulseGenerator1 | The source for the output statistics is set to Pulse Generator 1 - Applies to: CoaXPress. | |
TriggerOutSelectGPO6_PulseGenerator2 | The source for the output statistics is set to Pulse Generator 2 - Applies to: CoaXPress. | |
TriggerOutSelectGPO6_PulseGenerator3 | The source for the output statistics is set to Pulse Generator 3 - Applies to: CoaXPress. | |
TriggerOutSelectGPO6_VCC | A static one - Applies to: CoaXPress. |
Valid values for TriggerOutSelectGPO6.
enum TriggerOutSelectGPO7Enums#
Enumerator | Value | Description |
---|---|---|
TriggerOutSelectGPO7_BypassFrontGPI0 | Bypass the Front GPI 0 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO7_BypassFrontGPI1 | Bypass the Front GPI 1 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO7_BypassFrontGPI2 | Bypass the Front GPI 2 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO7_BypassFrontGPI3 | Bypass the Front GPI 3 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO7_BypassGPI0 | Bypass the GPI 0 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO7_BypassGPI1 | Bypass the GPI 1 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO7_BypassGPI2 | Bypass the GPI 2 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO7_BypassGPI3 | Bypass the GPI 3 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO7_BypassGPI4 | Bypass the GPI 4 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO7_BypassGPI5 | Bypass the GPI 5 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO7_BypassGPI6 | Bypass the GPI 6 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO7_BypassGPI7 | Bypass the GPI 7 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO7_CamAPulseGenerator0 | Camera port A Pulse Generator 0 - Applies to: CoaXPress. | |
TriggerOutSelectGPO7_CamAPulseGenerator1 | Camera port A Pulse Generator 1 - Applies to: CoaXPress. | |
TriggerOutSelectGPO7_CamAPulseGenerator2 | Camera port A Pulse Generator 2 - Applies to: CoaXPress. | |
TriggerOutSelectGPO7_CamAPulseGenerator3 | Camera port A Pulse Generator 3 - Applies to: CoaXPress. | |
TriggerOutSelectGPO7_CamBPulseGenerator0 | The output source is set to Cam B Pulse Generator 0 - Applies to: CoaXPress. | |
TriggerOutSelectGPO7_CamBPulseGenerator1 | The output source is set to Cam B Pulse Generator 1 - Applies to: CoaXPress. | |
TriggerOutSelectGPO7_CamBPulseGenerator2 | The output source is set to Cam B Pulse Generator 2 - Applies to: CoaXPress. | |
TriggerOutSelectGPO7_CamBPulseGenerator3 | The output source is set to Cam B Pulse Generator 3 - Applies to: CoaXPress. | |
TriggerOutSelectGPO7_CamCPulseGenerator0 | The output source is set to Cam C Pulse Generator 0 - Applies to: CoaXPress. | |
TriggerOutSelectGPO7_CamCPulseGenerator1 | The output source is set to Cam C Pulse Generator 1 - Applies to: CoaXPress. | |
TriggerOutSelectGPO7_CamCPulseGenerator2 | The output source is set to Cam C Pulse Generator 2 - Applies to: CoaXPress. | |
TriggerOutSelectGPO7_CamCPulseGenerator3 | The output source is set to Cam C Pulse Generator 3 - Applies to: CoaXPress. | |
TriggerOutSelectGPO7_CamDPulseGenerator0 | The output source is set to Cam D Pulse Generator 0 - Applies to: CoaXPress. | |
TriggerOutSelectGPO7_CamDPulseGenerator1 | The output source is set to Cam D Pulse Generator 1 - Applies to: CoaXPress. | |
TriggerOutSelectGPO7_CamDPulseGenerator2 | The output source is set to Cam D Pulse Generator 2 - Applies to: CoaXPress. | |
TriggerOutSelectGPO7_CamDPulseGenerator3 | The output source is set to Cam D Pulse Generator 3 - Applies to: CoaXPress. | |
TriggerOutSelectGPO7_GND | A static zero - Applies to: CoaXPress. | |
TriggerOutSelectGPO7_NotBypassFrontGPI0 | The output source is set to Not Bypass Front-GPI 0 - Applies to: CoaXPress. | |
TriggerOutSelectGPO7_NotBypassFrontGPI1 | The output source is set to Not Bypass Front-GPI 1 - Applies to: CoaXPress. | |
TriggerOutSelectGPO7_NotBypassFrontGPI2 | The output source is set to Not Bypass Front-GPI 2 - Applies to: CoaXPress. | |
TriggerOutSelectGPO7_NotBypassFrontGPI3 | The output source is set to Not Bypass Front-GPI 3 - Applies to: CoaXPress. | |
TriggerOutSelectGPO7_NotBypassGPI0 | Bypass the inverted GPI 0 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO7_NotBypassGPI1 | Bypass the inverted GPI 1 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO7_NotBypassGPI2 | Bypass the inverted GPI 2 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO7_NotBypassGPI3 | Bypass the inverted GPI 3 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO7_NotBypassGPI4 | Bypass the inverted GPI 4 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO7_NotBypassGPI5 | Bypass the inverted GPI 5 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO7_NotBypassGPI6 | Bypass the inverted GPI 6 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO7_NotBypassGPI7 | Bypass the inverted GPI 7 signal directly to the output - Applies to: CoaXPress. | |
TriggerOutSelectGPO7_NotCamAPulseGenerator0 | Inverted signal of camera port A Pulse Generator 0 - Applies to: CoaXPress. | |
TriggerOutSelectGPO7_NotCamAPulseGenerator1 | Inverted signal of camera port A Pulse Generator 1 - Applies to: CoaXPress. | |
TriggerOutSelectGPO7_NotCamAPulseGenerator2 | Inverted signal of camera port A Pulse Generator 2 - Applies to: CoaXPress. | |
TriggerOutSelectGPO7_NotCamAPulseGenerator3 | Inverted signal of camera port A Pulse Generator 3 - Applies to: CoaXPress. | |
TriggerOutSelectGPO7_NotCamBPulseGenerator0 | The output source is set to Not Cam B Pulse Generator 0 - Applies to: CoaXPress. | |
TriggerOutSelectGPO7_NotCamBPulseGenerator1 | The output source is set to Not Cam B Pulse Generator 1 - Applies to: CoaXPress. | |
TriggerOutSelectGPO7_NotCamBPulseGenerator2 | The output source is set to Not Cam B Pulse Generator 2 - Applies to: CoaXPress. | |
TriggerOutSelectGPO7_NotCamBPulseGenerator3 | The output source is set to Not Cam B Pulse Generator 3 - Applies to: CoaXPress. | |
TriggerOutSelectGPO7_NotCamCPulseGenerator0 | The output source is set to Not Cam C Pulse Generator 0 - Applies to: CoaXPress. | |
TriggerOutSelectGPO7_NotCamCPulseGenerator1 | The output source is set to Not Cam C Pulse Generator 1 - Applies to: CoaXPress. | |
TriggerOutSelectGPO7_NotCamCPulseGenerator2 | The output source is set to Not Cam C Pulse Generator 2 - Applies to: CoaXPress. | |
TriggerOutSelectGPO7_NotCamCPulseGenerator3 | The output source is set to Not Cam C Pulse Generator 3 - Applies to: CoaXPress. | |
TriggerOutSelectGPO7_NotCamDPulseGenerator0 | The output source is set to Not Cam D Pulse Generator 0 - Applies to: CoaXPress. | |
TriggerOutSelectGPO7_NotCamDPulseGenerator1 | The output source is set to Not Cam D Pulse Generator 1 - Applies to: CoaXPress. | |
TriggerOutSelectGPO7_NotCamDPulseGenerator2 | The output source is set to Not Cam D Pulse Generator 2 - Applies to: CoaXPress. | |
TriggerOutSelectGPO7_NotCamDPulseGenerator3 | The output source is set to Not Cam D Pulse Generator 3 - Applies to: CoaXPress. | |
TriggerOutSelectGPO7_NotPulseGenerator0 | Inverted signal of pulse generator 0 - Applies to: CoaXPress. | |
TriggerOutSelectGPO7_NotPulseGenerator1 | Inverted signal of pulse generator 1 - Applies to: CoaXPress. | |
TriggerOutSelectGPO7_NotPulseGenerator2 | Inverted signal of pulse generator 2 - Applies to: CoaXPress. | |
TriggerOutSelectGPO7_NotPulseGenerator3 | Inverted signal of pulse generator 3 - Applies to: CoaXPress. | |
TriggerOutSelectGPO7_PulseGenerator0 | The source for the output statistics is set to Pulse Generator 0 - Applies to: CoaXPress. | |
TriggerOutSelectGPO7_PulseGenerator1 | The source for the output statistics is set to Pulse Generator 1 - Applies to: CoaXPress. | |
TriggerOutSelectGPO7_PulseGenerator2 | The source for the output statistics is set to Pulse Generator 2 - Applies to: CoaXPress. | |
TriggerOutSelectGPO7_PulseGenerator3 | The source for the output statistics is set to Pulse Generator 3 - Applies to: CoaXPress. | |
TriggerOutSelectGPO7_VCC | A static one - Applies to: CoaXPress. |
Valid values for TriggerOutSelectGPO7.
enum TriggerOutStatisticsSourceEnums#
Enumerator | Value | Description |
---|---|---|
TriggerOutStatisticsSource_PulseGenerator0 | The source for the output statistics is set to Pulse Generator 0 - Applies to: CoaXPress. | |
TriggerOutStatisticsSource_PulseGenerator1 | The source for the output statistics is set to Pulse Generator 1 - Applies to: CoaXPress. | |
TriggerOutStatisticsSource_PulseGenerator2 | The source for the output statistics is set to Pulse Generator 2 - Applies to: CoaXPress. | |
TriggerOutStatisticsSource_PulseGenerator3 | The source for the output statistics is set to Pulse Generator 3 - Applies to: CoaXPress. |
Valid values for TriggerOutStatisticsSource.
enum TriggerOutputEventSelectEnums#
Enumerator | Value | Description |
---|---|---|
TriggerOutputEventSelect_PulseGenerator0 | The source for the output statistics is set to Pulse Generator 0 - Applies to: CoaXPress. | |
TriggerOutputEventSelect_PulseGenerator1 | The source for the output statistics is set to Pulse Generator 1 - Applies to: CoaXPress. | |
TriggerOutputEventSelect_PulseGenerator2 | The source for the output statistics is set to Pulse Generator 2 - Applies to: CoaXPress. | |
TriggerOutputEventSelect_PulseGenerator3 | The source for the output statistics is set to Pulse Generator 3 - Applies to: CoaXPress. |
Valid values for TriggerOutputEventSelect.
enum TriggerQueueModeEnums#
Enumerator | Value | Description |
---|---|---|
TriggerQueueMode_Off | The trigger queue mode is disabled - Applies to: CoaXPress. | |
TriggerQueueMode_On | The trigger queue mode is enabled - Applies to: CoaXPress. |
Valid values for TriggerQueueMode.
enum TriggerStateEnums#
Enumerator | Value | Description |
---|---|---|
TriggerState_Active | The trigger state is set to Active - Applies to: CoaXPress. | |
TriggerState_AsyncStop | The trigger state is set to AsyncStop - Applies to: CoaXPress. | |
TriggerState_SyncStop | The trigger state is set to SyncStop - Applies to: CoaXPress. |
Valid values for TriggerState.
enum VantagePointEnums#
Enumerator | Value | Description |
---|---|---|
VantagePoint_BottomLeft | Starting point of the image is the bottom left corner - Applies to: CoaXPress. | |
VantagePoint_BottomRight | Starting point of the image is the bottom right corner - Applies to: CoaXPress. | |
VantagePoint_TopLeft | Starting point of the image is the top left corner - Applies to: CoaXPress. | |
VantagePoint_TopRight | Starting point of the image is the top right corner - Applies to: CoaXPress. |
Valid values for VantagePoint.