Skip to content

PLCamera.TimerTriggerSourceEnum Class#

Sets the internal camera signal used to trigger the selected timer.

Applies to: CameraLink, ace 2 CXP, ace 2 GigE, ace 2 USB, ace GigE, ace USB, boost CoaXPress, dart GigE, dart USB, racer 2 CXP, racer 2S 5GigE, racer 2S CXP and racer 2S GigE

Visibility: Beginner

Selected by: TimerSelector

The feature documentation may provide more information.

Inheritance Hierarchy#

System.Object
  Basler.Pylon.ParameterListEnum
    Basler.Pylon.PLCamera.TimerTriggerSourceEnum

Constructors#

 NameDescription
Public methodPLCamera.TimerTriggerSourceEnum Initializes a new instance of the PLCamera.TimerTriggerSourceEnum class
 

Properties#

 NameDescription
Public propertyAcquisitionActive

The selected timer can be started by an Acquisition Active signal.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart GigE, dart USB, racer 2 CXP, racer 2S 5GigE, racer 2S CXP and racer 2S GigE

Public propertyAction1

The selected timer can be started by an action signal that is defined by action signal 1.

Applies to: ace 2 GigE, dart GigE, racer 2S 5GigE and racer 2S GigE

Public propertyAction2

The selected timer can be started by an action signal that is defined by action signal 2.

Applies to: ace 2 GigE

Public propertyCounter1Active

The selected timer can be started by a Counter 1 Active signal. By default, a Counter 1 Active signal is generated whenever counter 1 is started. You can change this behavior using the Counter Event Activation parameter.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart GigE, dart USB, racer 2 CXP, racer 2S 5GigE, racer 2S CXP and racer 2S GigE

Public propertyCounter1End

The selected timer can be started by a Counter 1 End signal. A Counter 1 End signal is generated whenever counter 1 is stopped, reset, or when it has reached its maximum value.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart GigE, dart USB, racer 2 CXP, racer 2S 5GigE, racer 2S CXP and racer 2S GigE

Public propertyCounter1Start

The selected timer can be started by a Counter 1 Start signal. A Counter 1 Start signal is generated whenever counter 1 is started.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart GigE, dart USB, racer 2 CXP, racer 2S 5GigE, racer 2S CXP and racer 2S GigE

Public propertyCounter2Active

The selected timer can be started by a Counter 2 Active signal. By default, a Counter 2 Active signal is generated whenever counter 2 is started. You can change this behavior using the Counter Event Activation parameter.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart GigE, dart USB, racer 2 CXP, racer 2S 5GigE, racer 2S CXP and racer 2S GigE

Public propertyCounter2End

The selected timer can be started by a Counter 2 End signal. A Counter 2 End signal is generated whenever counter 2 is stopped, reset, or when it has reached its maximum value.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart GigE, dart USB, racer 2 CXP, racer 2S 5GigE, racer 2S CXP and racer 2S GigE

Public propertyCounter2Start

The selected timer can be started by a Counter 2 Start signal. A Counter 2 Start signal is generated whenever counter 2 is started.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart GigE, dart USB, racer 2 CXP, racer 2S 5GigE, racer 2S CXP and racer 2S GigE

Public propertyCounter3Active

The selected timer can be started by a Counter 3 Active signal. By default, a Counter 3 Active signal is generated whenever counter 3 is started. You can change this behavior using the Counter Event Activation parameter.

Applies to: racer 2 CXP, racer 2S 5GigE, racer 2S CXP and racer 2S GigE

Public propertyCounter3End

The selected timer can be started by a Counter 3 End signal. A Counter 3 End signal is generated whenever counter 3 is stopped, reset, or when it has reached its maximum value.

Applies to: racer 2 CXP, racer 2S 5GigE, racer 2S CXP and racer 2S GigE

Public propertyCounter3Start

The selected timer can be started by a Counter 3 Start signal. A Counter 3 Start signal is generated whenever counter 3 is started.

Applies to: racer 2 CXP, racer 2S 5GigE, racer 2S CXP and racer 2S GigE

Public propertyCounter4Active

The selected timer can be started by a Counter 4 Active signal. By default, a Counter 4 Active signal is generated whenever counter 4 is started. You can change this behavior using the Counter Event Activation parameter.

Applies to: racer 2S 5GigE, racer 2S CXP and racer 2S GigE

Public propertyCounter4End

The selected timer can be started by a Counter 4 End signal. A Counter 4 End signal is generated whenever counter 4 is stopped, reset, or when it has reached its maximum value.

Applies to: racer 2S 5GigE, racer 2S CXP and racer 2S GigE

Public propertyCounter4Start

The selected timer can be started by a Counter 4 Start signal. A Counter 4 Start signal is generated whenever counter 4 is started.

Applies to: racer 2S 5GigE, racer 2S CXP and racer 2S GigE

Public propertyCxpTrigger0

The selected timer can be started by a CXP Trigger 0 signal.

Applies to: ace 2 CXP, boost CoaXPress, racer 2 CXP and racer 2S CXP

Public propertyCxpTrigger1

The selected timer can be started by a CXP Trigger 1 signal.

Applies to: ace 2 CXP, boost CoaXPress, racer 2 CXP and racer 2S CXP

Public propertyEncoder1

The selected timer can be started by an Encoder 1 signal.

Applies to: racer 2 CXP, racer 2S 5GigE, racer 2S CXP and racer 2S GigE

Public propertyEncoderReverse1

The selected timer can be started by an Encoder Reverse 1 signal.

Applies to: racer 2 CXP, racer 2S 5GigE, racer 2S CXP and racer 2S GigE

Public propertyExposureActive

The selected timer can be started by an Exposure Active signal. By default, an Exposure Active signal is generated whenever exposure is started. You can change this behavior using the Counter Event Activation parameter.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart GigE, dart USB, racer 2 CXP, racer 2S 5GigE, racer 2S CXP and racer 2S GigE

Public propertyExposureStart

The selected timer can be started by an Exposure Start signal.

Applies to: CameraLink, ace 2 CXP, ace 2 GigE, ace 2 USB, ace GigE, ace USB, boost CoaXPress, dart GigE, dart USB, racer 2 CXP, racer 2S 5GigE, racer 2S CXP and racer 2S GigE

Public propertyExposureTriggerWait

The selected timer can be started by an Exposure Trigger Wait signal.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart GigE, dart USB, racer 2 CXP, racer 2S 5GigE, racer 2S CXP and racer 2S GigE

Public propertyFlashWindow

The selected timer can be started by a Flash Window signal.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart GigE and dart USB

Public propertyFlashWindowStart

The timer can be triggered by the flash window start signal.

Applies to: ace GigE and ace USB

Public propertyFrameActive

The selected timer can be started by a Frame Active signal.

Applies to: racer 2S 5GigE, racer 2S CXP and racer 2S GigE

Public propertyFrameBurstActive

The selected timer can be started by a Frame Burst Active signal.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart GigE, dart USB, racer 2 CXP, racer 2S 5GigE and racer 2S GigE

Public propertyFrameBurstTriggerWait

The selected timer can be started by a Frame Burst Trigger Wait signal.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart GigE, dart USB, racer 2 CXP, racer 2S 5GigE and racer 2S GigE

Public propertyFrameTriggerWait

The selected timer can be started by a Frame Trigger Wait signal.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart GigE, dart USB, racer 2 CXP, racer 2S 5GigE, racer 2S CXP and racer 2S GigE

Public propertyFrequencyConverter

The selected timer can be started by a Frequency Converter signal.

Applies to: racer 2 CXP, racer 2S 5GigE, racer 2S CXP and racer 2S GigE

Public propertyLine1

The selected timer can be started by a Line 1 signal.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart GigE, dart USB, racer 2 CXP, racer 2S 5GigE, racer 2S CXP and racer 2S GigE

Public propertyLine2

The selected timer can be started by a Line 2 signal.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart USB, racer 2 CXP, racer 2S 5GigE, racer 2S CXP and racer 2S GigE

Public propertyLine3

The selected timer can be started by a Line 3 signal.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart GigE, dart USB, racer 2 CXP, racer 2S 5GigE, racer 2S CXP and racer 2S GigE

Public propertyLine4

The selected timer can be started by a Line 4 signal.

Applies to: dart USB

Public propertyLineTriggerWait

The selected timer can be started by a Line Trigger Wait signal.

Applies to: racer 2 CXP, racer 2S 5GigE, racer 2S CXP and racer 2S GigE

Public propertyName The full name of TimerTriggerSource (Overrides ParameterListEnum.Name.)
Public propertyOff

The selected timer is disabled and can't be started.

Applies to: CameraLink, ace 2 CXP, ace 2 GigE, ace 2 USB, ace GigE, boost CoaXPress, dart GigE, dart USB, racer 2 CXP, racer 2S 5GigE, racer 2S CXP and racer 2S GigE

Public propertyPeriodicSignal1

The selected timer can be started by a Periodic Signal 1 signal.

Applies to: ace 2 GigE, dart GigE, racer 2S 5GigE and racer 2S GigE

Public propertySoftwareSignal1

The selected timer can be started by a Software Signal 1 signal.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart GigE, dart USB, racer 2 CXP, racer 2S 5GigE, racer 2S CXP and racer 2S GigE

Public propertySoftwareSignal2

The selected timer can be started by a Software Signal 2 signal.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart GigE, dart USB, racer 2 CXP, racer 2S 5GigE, racer 2S CXP and racer 2S GigE

Public propertySoftwareSignal3

The selected timer can be started by a Software Signal 3 signal.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart GigE, dart USB, racer 2 CXP, racer 2S 5GigE, racer 2S CXP and racer 2S GigE

Public propertyTimer1Active

The selected timer can be started by a Timer 1 Active signal. By default, a Timer 1 Active signal is generated whenever timer 1 has been started. You can change this behavior using the Counter Event Activation parameter.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart GigE, dart USB, racer 2 CXP, racer 2S 5GigE, racer 2S CXP and racer 2S GigE

Public propertyTimer1End

The selected timer can be started by a Timer 1 End signal. A Timer 1 End signal is generated whenever timer 1 has elapsed.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart GigE, dart USB, racer 2 CXP, racer 2S 5GigE, racer 2S CXP and racer 2S GigE

Public propertyTimer2Active

The selected timer can be started by a Timer 2 Active signal. By default, a Timer 2 Active signal is generated whenever timer 2 is started. You can change this behavior using the Counter Event Activation parameter.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart GigE, dart USB, racer 2 CXP, racer 2S 5GigE, racer 2S CXP and racer 2S GigE

Public propertyTimer2End

The selected timer can be started by a Timer 2 End signal. A Timer 2 End signal is generated whenever timer 2 has elapsed.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart GigE, dart USB, racer 2 CXP, racer 2S 5GigE, racer 2S CXP and racer 2S GigE

 

Methods#

 NameDescription
Public methodToString The full name of TimerTriggerSource (Overrides Object.ToString()()()().)
 

PLCamera.TimerTriggerSourceEnum.ToString Method#

The full name of TimerTriggerSource

Return Value#

Type: String
Returns the full name of TimerTriggerSource

PLCamera.TimerTriggerSourceEnum Constructor#

Initializes a new instance of the PLCamera.TimerTriggerSourceEnum class

PLCamera.TimerTriggerSourceEnum.AcquisitionActive Property#

The selected timer can be started by an Acquisition Active signal.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart GigE, dart USB, racer 2 CXP, racer 2S 5GigE, racer 2S CXP and racer 2S GigE

PLCamera.TimerTriggerSourceEnum.Action1 Property#

The selected timer can be started by an action signal that is defined by action signal 1.

Applies to: ace 2 GigE, dart GigE, racer 2S 5GigE and racer 2S GigE

PLCamera.TimerTriggerSourceEnum.Action2 Property#

The selected timer can be started by an action signal that is defined by action signal 2.

Applies to: ace 2 GigE

PLCamera.TimerTriggerSourceEnum.Counter1Active Property#

The selected timer can be started by a Counter 1 Active signal. By default, a Counter 1 Active signal is generated whenever counter 1 is started. You can change this behavior using the Counter Event Activation parameter.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart GigE, dart USB, racer 2 CXP, racer 2S 5GigE, racer 2S CXP and racer 2S GigE

PLCamera.TimerTriggerSourceEnum.Counter1End Property#

The selected timer can be started by a Counter 1 End signal. A Counter 1 End signal is generated whenever counter 1 is stopped, reset, or when it has reached its maximum value.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart GigE, dart USB, racer 2 CXP, racer 2S 5GigE, racer 2S CXP and racer 2S GigE

PLCamera.TimerTriggerSourceEnum.Counter1Start Property#

The selected timer can be started by a Counter 1 Start signal. A Counter 1 Start signal is generated whenever counter 1 is started.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart GigE, dart USB, racer 2 CXP, racer 2S 5GigE, racer 2S CXP and racer 2S GigE

PLCamera.TimerTriggerSourceEnum.Counter2Active Property#

The selected timer can be started by a Counter 2 Active signal. By default, a Counter 2 Active signal is generated whenever counter 2 is started. You can change this behavior using the Counter Event Activation parameter.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart GigE, dart USB, racer 2 CXP, racer 2S 5GigE, racer 2S CXP and racer 2S GigE

PLCamera.TimerTriggerSourceEnum.Counter2End Property#

The selected timer can be started by a Counter 2 End signal. A Counter 2 End signal is generated whenever counter 2 is stopped, reset, or when it has reached its maximum value.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart GigE, dart USB, racer 2 CXP, racer 2S 5GigE, racer 2S CXP and racer 2S GigE

PLCamera.TimerTriggerSourceEnum.Counter2Start Property#

The selected timer can be started by a Counter 2 Start signal. A Counter 2 Start signal is generated whenever counter 2 is started.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart GigE, dart USB, racer 2 CXP, racer 2S 5GigE, racer 2S CXP and racer 2S GigE

PLCamera.TimerTriggerSourceEnum.Counter3Active Property#

The selected timer can be started by a Counter 3 Active signal. By default, a Counter 3 Active signal is generated whenever counter 3 is started. You can change this behavior using the Counter Event Activation parameter.

Applies to: racer 2 CXP, racer 2S 5GigE, racer 2S CXP and racer 2S GigE

PLCamera.TimerTriggerSourceEnum.Counter3End Property#

The selected timer can be started by a Counter 3 End signal. A Counter 3 End signal is generated whenever counter 3 is stopped, reset, or when it has reached its maximum value.

Applies to: racer 2 CXP, racer 2S 5GigE, racer 2S CXP and racer 2S GigE

PLCamera.TimerTriggerSourceEnum.Counter3Start Property#

The selected timer can be started by a Counter 3 Start signal. A Counter 3 Start signal is generated whenever counter 3 is started.

Applies to: racer 2 CXP, racer 2S 5GigE, racer 2S CXP and racer 2S GigE

PLCamera.TimerTriggerSourceEnum.Counter4Active Property#

The selected timer can be started by a Counter 4 Active signal. By default, a Counter 4 Active signal is generated whenever counter 4 is started. You can change this behavior using the Counter Event Activation parameter.

Applies to: racer 2S 5GigE, racer 2S CXP and racer 2S GigE

PLCamera.TimerTriggerSourceEnum.Counter4End Property#

The selected timer can be started by a Counter 4 End signal. A Counter 4 End signal is generated whenever counter 4 is stopped, reset, or when it has reached its maximum value.

Applies to: racer 2S 5GigE, racer 2S CXP and racer 2S GigE

PLCamera.TimerTriggerSourceEnum.Counter4Start Property#

The selected timer can be started by a Counter 4 Start signal. A Counter 4 Start signal is generated whenever counter 4 is started.

Applies to: racer 2S 5GigE, racer 2S CXP and racer 2S GigE

PLCamera.TimerTriggerSourceEnum.CxpTrigger0 Property#

The selected timer can be started by a CXP Trigger 0 signal.

Applies to: ace 2 CXP, boost CoaXPress, racer 2 CXP and racer 2S CXP

PLCamera.TimerTriggerSourceEnum.CxpTrigger1 Property#

The selected timer can be started by a CXP Trigger 1 signal.

Applies to: ace 2 CXP, boost CoaXPress, racer 2 CXP and racer 2S CXP

PLCamera.TimerTriggerSourceEnum.Encoder1 Property#

The selected timer can be started by an Encoder 1 signal.

Applies to: racer 2 CXP, racer 2S 5GigE, racer 2S CXP and racer 2S GigE

PLCamera.TimerTriggerSourceEnum.EncoderReverse1 Property#

The selected timer can be started by an Encoder Reverse 1 signal.

Applies to: racer 2 CXP, racer 2S 5GigE, racer 2S CXP and racer 2S GigE

PLCamera.TimerTriggerSourceEnum.ExposureActive Property#

The selected timer can be started by an Exposure Active signal. By default, an Exposure Active signal is generated whenever exposure is started. You can change this behavior using the Counter Event Activation parameter.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart GigE, dart USB, racer 2 CXP, racer 2S 5GigE, racer 2S CXP and racer 2S GigE

PLCamera.TimerTriggerSourceEnum.ExposureStart Property#

The selected timer can be started by an Exposure Start signal.

Applies to: CameraLink, ace 2 CXP, ace 2 GigE, ace 2 USB, ace GigE, ace USB, boost CoaXPress, dart GigE, dart USB, racer 2 CXP, racer 2S 5GigE, racer 2S CXP and racer 2S GigE

PLCamera.TimerTriggerSourceEnum.ExposureTriggerWait Property#

The selected timer can be started by an Exposure Trigger Wait signal.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart GigE, dart USB, racer 2 CXP, racer 2S 5GigE, racer 2S CXP and racer 2S GigE

PLCamera.TimerTriggerSourceEnum.FlashWindow Property#

The selected timer can be started by a Flash Window signal.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart GigE and dart USB

PLCamera.TimerTriggerSourceEnum.FlashWindowStart Property#

The timer can be triggered by the flash window start signal.

Applies to: ace GigE and ace USB

PLCamera.TimerTriggerSourceEnum.FrameActive Property#

The selected timer can be started by a Frame Active signal.

Applies to: racer 2S 5GigE, racer 2S CXP and racer 2S GigE

PLCamera.TimerTriggerSourceEnum.FrameBurstActive Property#

The selected timer can be started by a Frame Burst Active signal.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart GigE, dart USB, racer 2 CXP, racer 2S 5GigE and racer 2S GigE

PLCamera.TimerTriggerSourceEnum.FrameBurstTriggerWait Property#

The selected timer can be started by a Frame Burst Trigger Wait signal.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart GigE, dart USB, racer 2 CXP, racer 2S 5GigE and racer 2S GigE

PLCamera.TimerTriggerSourceEnum.FrameTriggerWait Property#

The selected timer can be started by a Frame Trigger Wait signal.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart GigE, dart USB, racer 2 CXP, racer 2S 5GigE, racer 2S CXP and racer 2S GigE

PLCamera.TimerTriggerSourceEnum.FrequencyConverter Property#

The selected timer can be started by a Frequency Converter signal.

Applies to: racer 2 CXP, racer 2S 5GigE, racer 2S CXP and racer 2S GigE

PLCamera.TimerTriggerSourceEnum.Line1 Property#

The selected timer can be started by a Line 1 signal.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart GigE, dart USB, racer 2 CXP, racer 2S 5GigE, racer 2S CXP and racer 2S GigE

PLCamera.TimerTriggerSourceEnum.Line2 Property#

The selected timer can be started by a Line 2 signal.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart USB, racer 2 CXP, racer 2S 5GigE, racer 2S CXP and racer 2S GigE

PLCamera.TimerTriggerSourceEnum.Line3 Property#

The selected timer can be started by a Line 3 signal.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart GigE, dart USB, racer 2 CXP, racer 2S 5GigE, racer 2S CXP and racer 2S GigE

PLCamera.TimerTriggerSourceEnum.Line4 Property#

The selected timer can be started by a Line 4 signal.

Applies to: dart USB

PLCamera.TimerTriggerSourceEnum.LineTriggerWait Property#

The selected timer can be started by a Line Trigger Wait signal.

Applies to: racer 2 CXP, racer 2S 5GigE, racer 2S CXP and racer 2S GigE

PLCamera.TimerTriggerSourceEnum.Name Property#

The full name of TimerTriggerSource

PLCamera.TimerTriggerSourceEnum.Off Property#

The selected timer is disabled and can't be started.

Applies to: CameraLink, ace 2 CXP, ace 2 GigE, ace 2 USB, ace GigE, boost CoaXPress, dart GigE, dart USB, racer 2 CXP, racer 2S 5GigE, racer 2S CXP and racer 2S GigE

PLCamera.TimerTriggerSourceEnum.PeriodicSignal1 Property#

The selected timer can be started by a Periodic Signal 1 signal.

Applies to: ace 2 GigE, dart GigE, racer 2S 5GigE and racer 2S GigE

PLCamera.TimerTriggerSourceEnum.SoftwareSignal1 Property#

The selected timer can be started by a Software Signal 1 signal.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart GigE, dart USB, racer 2 CXP, racer 2S 5GigE, racer 2S CXP and racer 2S GigE

PLCamera.TimerTriggerSourceEnum.SoftwareSignal2 Property#

The selected timer can be started by a Software Signal 2 signal.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart GigE, dart USB, racer 2 CXP, racer 2S 5GigE, racer 2S CXP and racer 2S GigE

PLCamera.TimerTriggerSourceEnum.SoftwareSignal3 Property#

The selected timer can be started by a Software Signal 3 signal.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart GigE, dart USB, racer 2 CXP, racer 2S 5GigE, racer 2S CXP and racer 2S GigE

PLCamera.TimerTriggerSourceEnum.Timer1Active Property#

The selected timer can be started by a Timer 1 Active signal. By default, a Timer 1 Active signal is generated whenever timer 1 has been started. You can change this behavior using the Counter Event Activation parameter.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart GigE, dart USB, racer 2 CXP, racer 2S 5GigE, racer 2S CXP and racer 2S GigE

PLCamera.TimerTriggerSourceEnum.Timer1End Property#

The selected timer can be started by a Timer 1 End signal. A Timer 1 End signal is generated whenever timer 1 has elapsed.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart GigE, dart USB, racer 2 CXP, racer 2S 5GigE, racer 2S CXP and racer 2S GigE

PLCamera.TimerTriggerSourceEnum.Timer2Active Property#

The selected timer can be started by a Timer 2 Active signal. By default, a Timer 2 Active signal is generated whenever timer 2 is started. You can change this behavior using the Counter Event Activation parameter.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart GigE, dart USB, racer 2 CXP, racer 2S 5GigE, racer 2S CXP and racer 2S GigE

PLCamera.TimerTriggerSourceEnum.Timer2End Property#

The selected timer can be started by a Timer 2 End signal. A Timer 2 End signal is generated whenever timer 2 has elapsed.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart GigE, dart USB, racer 2 CXP, racer 2S 5GigE, racer 2S CXP and racer 2S GigE